16
Connect Electrical Supply
9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
This appliance is connected with a plug
▯
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
▯
The appliance must be properly grounded.
▯
Plug must be rated not less than type 6-20 P
(2-pole 3-wire grounding).
▯
Only a qualified electrician should connect the
plug.
▯
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.
Ventilation molding
If downdraft ventilation is used next to a gas appliance,
a ventilation molding AA 414 010 must be fitted on the
gas appliance during cooking. The ventilation molding
improves extraction when using gas appliances. The
ventilation molding prevents extinction of small flames
due to the draft.
Removing appliance
Disconnect the appliance from the power supply. For
flush-mounted appliances, remove the silicone joint.
Push out the appliance from below.
9
CAUTION
Damage to appliance! Don't lever device out from
above at the frame.
AA 414 010
Ventilation molding, for operation next
to the VG 414/415/424/425 gas
appliance