15
REV 5/22
GB752SVSRVT
-
5 INSTALLATION TOOL
S/N: 1001 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
REMOVING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Remove lever assembly (724017) including spring pin (A
-
1174).
2.
With lever assembly (724017) removed, insert a
5/8”
open end box wrench around actuator
assembly
-
air (704130).
3.
Loosen the actuator assembly
-
air (704130).
4. Remove wrench. Unthread and remove the actuator assembly
-
air (704130) with fingers from
the manifold head assembly (744306).
INSTALLING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Apply Teflon® tape onto threads of actuator assembly
-
air (704130) one to two wraps.
2.
Thread the actuator assembly
-
air (704130) all the way into manifold head assembly (744306) with
fingers.
3.
Insert and turn
5/8”
open end box wrench and snug tight approximately 1/4
-
1/2 turn.
4.
Re
-
attach the lever assembly (724017) including spring pin (A
-
1174).
ACTUATOR ASSEMBLY
-
AIR
WARNING
:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may occur if
power source is not disconnected.
CAUTION:
Actuator assembly
-
air (704130) can break if not careful.
CAUTION:
Do not over tighten actuator assembly
-
air (704130). Snug tighten only.
OVERHAUL
Image may not
reflect actual tool.