REV. 6/23
15
GB734SRVT5 INSTALLTION TOOL
SN#1002 AND ABOVE
OVERHAUL
ACTUATOR ASSEMBLY
-
AIR
WARNING
:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may occur
if power source is not disconnected.
CAUTION:
Actuator assembly
-
air (704130) can break if not careful.
CAUTION:
Do not over tighten actuator assembly
-
air (704130). Snug tighten only.
REMOVING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Remove actuator lever assembly (724017) including pin.
2.
With actuator lever assembly (724017) removed, insert a
5/8”
open end box wrench / adjustable wrench
around actuator assembly
-
air (704130).
3.
Loosen the actuator assembly
-
air (704130).
4. Remove wrench. Unthread and remove the actuator assembly
-
air (704130) with fingers from the
manifold head (744306).
INSTALLING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Apply Teflon® tape onto threads of actuator assembly
-
air (704130) one to two wraps.
2.
Thread the actuator assembly
-
air (704130) all the way into manifold head (744306) with fingers.
3.
Insert and turn
5/8”
open end box wrench / adjustable wrench and snug tight approximately 1/4
-
1/2 turn.
4.
Re
-
attach the actuator lever assembly (724017) with pin.
Image may not
reflect actual tool