8
Rev. 5/22
S/N: 3158 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
HOW TO SET
-
UP THE GB703VT
The tool is shipped with a plastic plug in the air inlet connector. The connector has a 1/4
-
18 female pipe thread to accept user air hose
fitting. The tool comes with oil and is ready to use.
1. Remove plastic shipping plug from (A
-
506) (air inlet) and screw in your quick disconnect (air) fitting.
2. Attach Evacuation tube to fitting on rear of head cylinder assembly (703109).
3. Connect tool to air hose with 90 psi. (6.2 bar) using clean, dry air.
3/8” (9.52
mm) minimum diameter air line is recommended.
Cycle tool five times by depressing and releasing actuator lever assembly (704343).
4. Disconnect air hose from tool.
5.
Select proper nose assembly (see accessories pg. 19 for more information). Apply Vibra
-
tite® pt. #405125 to all threads and allow
it to set 20 minutes prior to assembly. Screw collet onto piston and slide anvil over collet and secure with jam nut (70820). (See
proper data sheet for further instructions).
6.
Connect air supply.
USER QUICK
DISCONNECT FITTING
AIR HOSE
RED SHIPPING PLUG
AIR INLET
HEAD CYLINDER ASSEMBLY
NOSE ASSEMBLY
FASTENER
WORK
ACTUATOR
Image may not reflect actual tool
EVACUATION TUBE
FITTING
WARNING:
Only qualified and trained operators must install, adjust or use the assembly power tool for non
-
threaded
mechanical fasteners.
WARNING:
Operator
MUST
read and understand all warnings and cautions.
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user
’
s employer must assess specific risks that could be present as a result after each use
based on their application.
●
Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
●
Verify
the air lines and/or hydraulic hoses are not a trip hazard.
●
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from operator, other
persons working in the vicinity, foreign matter and liquid.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start
-
up.
WARNING:
Ensure there is adequate clearance for tool and operator hands.
WARNING:
Do not operate this tool without deflector, pintail catcher bag or pintail collection bottle in place.
CAUTION:
Do not use beyond the design intent.