background image

 

PROG

c

>10 sec.

OK

1
2

3
4
5
6
7

c

número
de menú

OK

1
2

3
4
5
6
7

OK

1
2

3
4
5
6
7

c

c

 
CONFIGURATION 

 
It is possible to configure various parameters of the unit.  
 
 
 

In OFF mode press for 10 seconds 

ON/OFF

key to enter the first configuration  

menu. It is necessary to pass through five menus to exit the configuration. The 
Menu number is displayed above in the right part of the display.  
 
 
 
 
 
 
 
 
 
 
 
 

 

Menu 1: Adjusting the ECO set point temperature.  

 
By default the Economic set point temperature value is equal to 
comfort temperature value reduced by 3,5ºC.  
 
The reduction value may be modified from 0 a 10ºC in 0,5°C steps.    

For this purpose modify the value with the keys 

“+”

 

/

 

“–” 

and press

 

OK

” 

to store 

and pass to the next setting.  
 
 
 
 
 
 
 
 
 
ECO set point temperature value may be stored independently from the CONFORT 
temperature value.  
 

To authorize ECO value modification press and hold the 

“+”

key until it displays the 

message "

----

 and store pressing 

OK

 
 
 
 
In such a way when selecting the permanent economical mode it 

will be possible to assign any temperature with 

“+”

 

or

  

“–” 

key displayed at selection of 

permanent economical mode.  
 
 
Selection range will start from 4.5ºC to the comfort set point temperature.  
 
 

 
 
 
Menu 2: Correction of temperature measures.  

 
If there is a difference between an external thermometer indication and the temperature 
displayed by the unit, in menu 2 it is possible to influence on the sensor in order to balance 
the difference. (-5ºC to +5ºC,) in 0,1ºC steps.  

To modify press the keys 

“+”

 

or

  

“–”

, after press the 

OK

” 

 

key and proceed with the 

next setting.   
 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for RKS4Hi

Page 1: ...R GUIDE INTERTIA ELECTRIC RADIATOR RKS4Hi RKS6Hi RKS8Hi RKS10Hi RKS12Hi RKS14Hi RKS4L RKS6L RKS8L RKS10L RKS12L RKS14L Please read these instructions before installing or using this appliance for the...

Page 2: ...o be taken during the times of the year when heat is not required The thermal radiator should not be installed just below an electrical socket or in front of a socket outlet The appliance must be inst...

Page 3: ...change the sensor settings in order to balance the difference 5 C to 5 C in 0 5 C steps In order to make changes hold the mod key for more than five seconds and after that with buttons or increase or...

Page 4: ...and FROST PROTECTION are prior and independent from the operation mode selected in the heater OPERATION WITH A PROGRAMMER WITH POWER LINE CARRIER OR A LOAD CONTROLER WITH POWER LINE CARRIER In AUTOMAT...

Page 5: ...the operation to set minutes Press the ON OFF key to exit These four keys perform different operations depending on the message of the LCD display Press two central buttons at a time for several secon...

Page 6: ...T FROST PROTECTION MODE AUTOMATIC REMOTE PROGRAMMER MODE 1 2 3 4 5 6 7 PROG AUTO c 0h 2 4 6 8 10 12 14 16 18 20 22 24 c AUTO c c When the unit is in OFF symbol is displayed together with premises temp...

Page 7: ...tarily the premises temperature PERMANENT FROST PROTECTION MODE In permanent frost protection mode the unit will operate when the premises temperature decreases lower than 7 C In this mode pressing th...

Page 8: ...control To unlock the keyboard press simultaneously central keys and for several seconds OK SAND GLASS KEY Press the key to adjust the specified temperature for certain determined time By keys or adju...

Page 9: ...d press OK to store and pass to the next setting ECO set point temperature value may be stored independently from the CONFORT temperature value To authorize ECO value modification press and hold the k...

Page 10: ...ds Clean dust with a dry soft cloth only when the unit is disconnected and cold Do not use solvents or abrasive products for cleaning After the heating season disconnect the radiator with the switch l...

Page 11: ...5 cm separation from the wall HEIGHT cm 58 WEIGHT 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg POWER 500W 750W 1000W 1250W 1600W 2000W 500W 750W 1000W 1250W 1600W 2000W ISOLA...

Page 12: ...er the heater The symbol on the product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the...