background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Connection and Disconnection 

 

Each ECOHHR storage heaters has its own power switch 
and is located on the right side panel. The power switch is 
used to turn the heater ON and OFF. 
 
If this switch is turned OFF then the storage heater will not 
take a charge when the off peak supply is on and will not 
give out any heat. Therefore it is important to make sure 
this is turned ON at all times. 
 
 
 

 
 
 

Each  ECOHHR storage heater requires two electrical 
supplies. One is an economy tariff supply (off peak or 
restricted supply) and the other is a 24hr supply (on peak 
or unrestricted supply). 
 
Connection from the economy supply (off peak or restricted 
supply) to the heater should be via  a 20Amp double pole 
isolator switch. 
Connection from the 24hr supply (on peak or unrestricted 
supply) to the heater should be via a fused double pole 
isolator switch or a fused RCD isolator switch, depending 
on the installation. 

User Control Panel 

 
You will find the keypad on the top right side on the heater. 
This easy to use keypad only has four buttons, however 
these four button can be use in different ways to give you 
many functions and will be explained in more detail in later 
sections. 
 

Basic Key functions: 
 

 

 

This button is used to set the 

'Comfort'

 

 

 

 

temperature. Default is 21°C. 

 
 

 

This button is used to set the 

'Economy'

 

 

 

temperature. Default is 18°C. 

 

 

 

This button is used to decrease values. 

 
 
 

 

This button is used to increase values. 

 
 

 
       and 

Pressing these buttons together will allow 

 

 

you to set the Day and Time. 

 
 
       and 

Pressing these buttons together will allow 

 

 

you to set the weekly program. 

User Operating Instructions 

Note: Two electrical supplies needed. 

        Economy

 and 

24hr

 supply. 

Summary of Contents for Ecombi HHR Series

Page 1: ......

Page 2: ...m the 24hr supply on peak or unrestricted supply to the heater should be via a fused double pole isolator switch or a fused RCD isolator switch depending on the installation User Control Panel You wil...

Page 3: ...ese steps and Press and Hold the sun button and the minus button together until the Day is displayed and starts to flash Use the plus or minus buttons to adjust to the current Day and Press and Releas...

Page 4: ...and Release the sun comfort button again to set the new comfort temperature level Setting the Economy Temperature Level The ECOHHR storage heater has been preset with an Economy temperature level of...

Page 5: ...ou want the heater to be at the Comfort and Economy temperatures Press and Release the moon economy button and the plus button at the same time The word ProG will display for a short time and then dAY...

Page 6: ...and repeat the above for day 2 and the other days or copy day1 to day2 day2 to day3 day3 to day4 and so on 5 User Operating Instructions Repeat above steps and go through all 24 hours until dAY1 or p...

Page 7: ...ater will then continue to run your current program 6 Control Panel Child Lock Function The ECOHHR storage heater has a built in child lock function that allows you to block any unwanted changes to th...

Page 8: ...tons together The display will now show the current room temperature that the sensor is measuring Now Press and Release the plus button to see the current Core temperature Now Press and Release the pl...

Reviews: