background image

 

 

3 – EMITTER MODE: 

 
 

This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating.   

Press the 

  key several times until the message 

 is displayed.  

 

“Е”

 stands for EMITTER. 

“21.5” stands for the set up temperature in ºC. 

Emitter will operate until the temperature in the room reach 21,5ºC, then, it will maintain the temperature. 

If needed, it is possible to change the set up temperature by using the keys 

 and 

. Temperature value will be 

changing in steps of 0,5ºC.  
 

Small red dot at the very right part of the display will show that the convector heating element is working at that moment. 

 

Pressing simultaneously keys 

 and 

 will display room temperature taken from the sensor at the bottom of the 

device. 
It can be the case of a temperature difference between this sensor and a normal thermometer set up in a wall room. This is 

because temperature is different at different heights in the room. The one at the floor is normally lower. User can adjust the 

sensor so that different thermometers show  same temperature. For this you can go to General Settings part and modify the 
sensor reading according to P5 setting. 

 

 

4 – ECOMBI MANUAL MODE: 

 

This mode will allow ECOMBI to operate the Storage Heater and the Convector together in a combined way. The Storage 
Heater will charge based on the settings of “AUTOMATIC STORAGE HEATER MODE” and if there is any kind of heat loss in 

the room and a decrease in the temperature, ECOMBI may operate the “EMITTER MODE” to compensate and balance again the 

room temperature. 

To select this mode press the key 

 several times until in the display only appears the set up temperature. This is without 

any preceding letter “A” or “E” displayed. I.e. 

. This means that 21,5ºC is the system set up temperature (default).  

It is possible to adjust the set up temperature by using the keys 

 and  

 . Temperature value will be changing in 

steps of 0,5ºC.  

 

When the convector heating element is working a small red dot will appear at the very right part of the display.  

 
In this mode, the set up temperature is independent from the set up charging %. Default setting for charging % is 4 (80%). Please 

read under “STORAGE HEATER mode” if you want to modify it.  

 

While ECOMBI is charging (electric consumption) a small red dot will appear on the left side of the display 

 . 

 

Storage Heater and Convector never work at the same time. This is, both powers never are added. Emitter may operate at any 
time of the day or the night, including off-peak periods, but only if Storage Heater is not charging.  

 

 

5 -ECOMBI AUTOMATIC MODE, with charge correction. 

 

In this mode  ECOMBI operates in a combined way. Storage heater operates during off peak rate, and when it is not being 

charged,  ECOMBI may operate as Emitter providing additional heating to the room if necessary.  
BESIDES THIS THERE WILL BE AN AUTOMATIC CHARGE CORRECTION OF THE STORAGE HEATER FOR THE 

FOLLOWING DAYS.  

To activate this mode press the 

  key for several times until the message 

 is displayed.  

 

А

 stands for AUTOMATIC mode.  

21,5  is the set up temperature in ºC.  

When the Emitter is on, a small red dot at the very right of the screen will be displayed.  

Summary of Contents for ECO1

Page 1: ...ECOMBI ECO1 ECO2 ECO3 ECO4 INSTALLATION MANUAL AND USER GUIDE Please read these instructions CAREFULLY before installing or using this appliance for the first time ...

Page 2: ...er should be switched off at the isolating switch before any repair work is carried out This action should also be taken during the times of the year when heat is not required This appliance is only for permanent connection to a fix installation The installation of the heaters must be carried out in such a way that each pole can be disconnected from the supply having a contact separation of at lea...

Page 3: ...ndicated minimum clearance is allowed from the appliance to any combustible material such as furniture or curtains 2 Open the carton at the indicated side and fix the supporting feet without removing the heater Turn the carton upside down to allow the heater to stand on its feet and remove the carton Check that it is the correct model and that it is in good conditions CURTAIN PIECE OF FURNITURE OB...

Page 4: ...EWS these are used only to prevent the device from overturning and not to support it If there is any doubt concerning the wall strength consult the corresponding construction specialist The appliances are heavy it is the installer responsibility the correct installation and wall support of these devices to prevent them from overturning 6 Connect the heater using the wiring diagram included in the ...

Page 5: ...this inner panel there is a very delicate thermal insulation MICROTHERM panel It has to be handled with extreme care AVOID TOUCHING IT 8 Do not disconnect the electrical heating elements Remove the protection cardboards Lift and recline the elements caring about not breaking their insulation ...

Page 6: ...efit the inner front panel If the bricks have been fitted correctly you will find no difficulty in refitting this panel Please check the insulation panel is also properly fitted Please see below 12 Connect again the two Faston connectors to the aluminum heating element and to the safety thermostat 13 Fit again the exterior front panel by connecting first the joints in its upper part Then push its ...

Page 7: ...ngs part In order to set the system time hold the key for 8 seconds The Hour values are changed with the and keys Then press the key to save and proceed to change the minutes values Press again to save and proceed to change the week day if weekly programming option is enabled in the GENERAL SETIINGS part In the case it is necessary to set up different values for different days in a week please go ...

Page 8: ... 3 5 70 3 0 60 2 5 50 2 0 40 1 5 30 1 0 20 0 5 10 0 0 0 While ECOMBI is charging electric consumption a small red dot will appear between the A and the C in the display DEFERRED CHARGING This function in ECOMBI allows optimizing the energy management and consumption In a off peak period of 8 hours if there is the case where it is only necessary to charge at 50 this is 4 hours This function will ma...

Page 9: ... may operate the EMITTER MODE to compensate and balance again the room temperature To select this mode press the key several times until in the display only appears the set up temperature This is without any preceding letter A or E displayed I e This means that 21 5ºC is the system set up temperature default It is possible to adjust the set up temperature by using the keys and Temperature value wi...

Page 10: ...le to select which days ECOMBI will work and which days will not be working By activating P7 in GENERAL SETTINGS this option will be enabled To enter in weekly settings please hold the key for 8 seconds Blinking hours will be displayed Press the key then blinking minutes will be displayed Press the key then the first day of the week will blink Change the week day if necessary with the keys and Pre...

Page 11: ...all of them to the last one PA DEFAULT SETTINGS By pushing the Clock key of the device connected to the mains Software resets to the default settings Four horizontal blinking segments will appear in the screen to confirm it 4 MAINTENANCE ECOMBI does not need any special maintenance Clean and dust with a dry soft cloth only when the unit is disconnected and cold Do not use any solvent or abrasive p...

Page 12: ...ctronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you p...

Reviews: