GENERAL SETTINGS: 

 

ECOMBI general operation settings can be modified. 
 

By pressing the  

 key at the same time we connect the device with the mains switch located at the right side panel, we 

enter to the general settings menu. This is: 

 

P1   

Starting time of reduced (off peak) rate electric period. 

P2   

Ending time of reduced rate electric period. 

P3   

Starting time of the second reduced rate electric period (if not available set up 00.00). 

P4   

Ending time of the second reduced rate period (if not available set up 00.00) 

P5   

Temperature sensor correction (values from -5ºC to +5ºC) 

 P6  

Deferred charge ON: charge ends at the same time than reduce rate period. 

OFF: charge stars at the same time than reduce rate period... 

P7   

Weekly programming ON/OFF. 

P8 

Limit factor of emitter operation mode to increase or reduce the charge 
(Possible values 0.05 - 0.10 - 0.15 - 0.20 - 0.25 - 0.30 - 0.35 - 0.40) 

P9   

Percentage of automatic charge regulation (values: 05-10-20-25) 

PA 

Excess of temperature protection during the charge. Degrees higher than the set up 
temperature when the charge is interrupted. (Values 1 - 2 - 3 - 4 - 5) 

 

Advance with the keys 

 and 

, push the 

 key to enter in a parameter. Use same keys to modify it.  

 

To save the new values it is necessary to pass through all of them to the last one (PA).  
 

 

DEFAULT SETTINGS: 

 
By pushing the Clock key of the device connected to the mains. Software resets to the default settings. Four horizontal blinking 

segments will appear in the screen to confirm it. 

 
 

4.- MAINTENANCE 

 

ECOMBI does not need any special maintenance. 
Clean and dust with a dry, soft cloth only when the unit is disconnected and cold. 
Do not use any solvent or abrasive product for cleaning. 
When the Heating season is finished, please disconnect the device by the mains switch located at the right back lateral of the 
unit. 
ECOMBI has been manufactured under a fully assured quality system and using environment friendly processes. 
Once its useful life is finished please take the device to a clean point so that its components can be recycled in an adequate way. 
 
 

5.- TROUBLESHOOTING 

 

 

ECOMBI does not heat. 

Please check it is connected and switched on. 
Make sure the device is not covered or the lower air inlets are not obstructed. May be the LR limit 
thermostat is activated; in this case it is necessary to rearm it manually. 

ECOMBI does not reach set up 
temperature 

Make sure that adequate temperature is selected. 
Make sure room heat looses fit the power of the device.

 

ERR 1 in display 

Temperature sensor trouble, please do contact to the technical assistance. 

Key board does not respond 

If display shows [ - - ] display is blocked. Press at the same time “+” and “-”  key during some seconds 
to unblock it.. 

 

 

 

Summary of Contents for ECO1

Page 1: ...ECOMBI ECO1 ECO2 ECO3 ECO4 INSTALLATION MANUAL AND USER GUIDE Please read these instructions CAREFULLY before installing or using this appliance for the first time ...

Page 2: ...er should be switched off at the isolating switch before any repair work is carried out This action should also be taken during the times of the year when heat is not required This appliance is only for permanent connection to a fix installation The installation of the heaters must be carried out in such a way that each pole can be disconnected from the supply having a contact separation of at lea...

Page 3: ...ndicated minimum clearance is allowed from the appliance to any combustible material such as furniture or curtains 2 Open the carton at the indicated side and fix the supporting feet without removing the heater Turn the carton upside down to allow the heater to stand on its feet and remove the carton Check that it is the correct model and that it is in good conditions CURTAIN PIECE OF FURNITURE OB...

Page 4: ...EWS these are used only to prevent the device from overturning and not to support it If there is any doubt concerning the wall strength consult the corresponding construction specialist The appliances are heavy it is the installer responsibility the correct installation and wall support of these devices to prevent them from overturning 6 Connect the heater using the wiring diagram included in the ...

Page 5: ...this inner panel there is a very delicate thermal insulation MICROTHERM panel It has to be handled with extreme care AVOID TOUCHING IT 8 Do not disconnect the electrical heating elements Remove the protection cardboards Lift and recline the elements caring about not breaking their insulation ...

Page 6: ...efit the inner front panel If the bricks have been fitted correctly you will find no difficulty in refitting this panel Please check the insulation panel is also properly fitted Please see below 12 Connect again the two Faston connectors to the aluminum heating element and to the safety thermostat 13 Fit again the exterior front panel by connecting first the joints in its upper part Then push its ...

Page 7: ...ngs part In order to set the system time hold the key for 8 seconds The Hour values are changed with the and keys Then press the key to save and proceed to change the minutes values Press again to save and proceed to change the week day if weekly programming option is enabled in the GENERAL SETIINGS part In the case it is necessary to set up different values for different days in a week please go ...

Page 8: ... 3 5 70 3 0 60 2 5 50 2 0 40 1 5 30 1 0 20 0 5 10 0 0 0 While ECOMBI is charging electric consumption a small red dot will appear between the A and the C in the display DEFERRED CHARGING This function in ECOMBI allows optimizing the energy management and consumption In a off peak period of 8 hours if there is the case where it is only necessary to charge at 50 this is 4 hours This function will ma...

Page 9: ... may operate the EMITTER MODE to compensate and balance again the room temperature To select this mode press the key several times until in the display only appears the set up temperature This is without any preceding letter A or E displayed I e This means that 21 5ºC is the system set up temperature default It is possible to adjust the set up temperature by using the keys and Temperature value wi...

Page 10: ...le to select which days ECOMBI will work and which days will not be working By activating P7 in GENERAL SETTINGS this option will be enabled To enter in weekly settings please hold the key for 8 seconds Blinking hours will be displayed Press the key then blinking minutes will be displayed Press the key then the first day of the week will blink Change the week day if necessary with the keys and Pre...

Page 11: ...all of them to the last one PA DEFAULT SETTINGS By pushing the Clock key of the device connected to the mains Software resets to the default settings Four horizontal blinking segments will appear in the screen to confirm it 4 MAINTENANCE ECOMBI does not need any special maintenance Clean and dust with a dry soft cloth only when the unit is disconnected and cold Do not use any solvent or abrasive p...

Page 12: ...ctronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you p...

Reviews: