background image

 

 

EN 

Press the power switch and fan switch in the opposite direction, then the appliance will stop working. 
 
Finally, unplug the appliance from the socket after using. 

4.- CLEANING AND MAINTENANCE 

The panel heaters do not precise any special maintenance providing thermal comfort during large periods.  Clean dust with a 
dry, soft cloth only when the unit is disconnected and cold.  
Do not use solvents or abrasive products for cleaning. 
 
This panel heater has been manufactured under an assured quality system using environment friendly processes.  
Please take the panel heaters to a clean point once their useful life is finished, in order to recycle their materials in the right 
way. 
 

5.- SPECIFICATIONS 

 

Model 

CP - 2000 

Power 

2000 W 

Power Levels 

3 levels (2000 / 1250 / 750 W) 

Width 

69 cm 

Depth 

18,5 cm 

Height 

42 cm 

Weight 

3,3 kg 

Voltage 

220 - 240 V 

 

Isolation 

Class I 

 
6.- PRODUCT FICHE 

 

Item 

Symbol 

Value 

Unit 

CP - 2000 

Heat Output

 

Nominal heat output 

P

nom 

2,0 

kW 

Minimum heat output 

P

min 

0,75 

kW 

Maximum continuous heat output 

P

max,c 

2,0 

kW 

Auxiliary electricity consumption

 

At nominal heat output 

el

max 

0,000 

kW 

At minimum heat output 

el

min 

0,000 

kW 

In standby mode 

el

SB 

<0,0005 

kW 

 

Item 

Value 

Type of heat output / room temperature control

 

With mechanic thermostat room temperature control 

Yes 

 

Contact details 

ELNUR, S.A.  
Travesía de Villa Esther, 11 
28110 

 Algete (Madrid), Spain 

 

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric portable local space 

heater. 

 

Summary of Contents for CP Series

Page 1: ...la no observancia de estas instrucciones no ser cubierto por la garant a del fabricante Este manual debe ser guardado con el aparato por el usuario para futuras consultas Please read these instructio...

Page 2: ...ruyendoelflujodeaire Esteconvectordebeserdesconectadodelaredel ctricaantesdeefectuarcualquierreparaci nensuinterior Siquieredejar fueradeservicioelaparatodescon ctelodelainstalaci n Elconvectornodebes...

Page 3: ...n en un enchufe con salida 220 240 V Pulse los interruptores de potencia 750W o 1250W en funci n de la potencia requerida Pulse ambos al mismo tiempo en caso de que se requiera la m xima potencia 2000...

Page 4: ...io para que sus materiales puedan ser reciclados de forma adecuada 5 ESPECIFICACIONES T CNICAS Modelo CP 2000 Potencia 2000 W Niveles de Potencia 3 niveles 2000 1250 750 W Ancho 69 cm Profundidad 18 5...

Page 5: ...rovidedtoensurethemostefficient operationoftheappliance Theyalsoprotecttheheaterfromoverheating therefore itisessentialthatatnotimearethey covered Thisheatershouldbeswitchedoffattheisolatingswitchbefo...

Page 6: ...witch to 750W or 1250W depending on the required power or press both 750W 1250W at the same time for 2000W power The indicator light will be on Set the thermostat switch to maximum and operate the app...

Page 7: ...recycle their materials in the right way 5 SPECIFICATIONS Model CP 2000 Power 2000 W Power Levels 3 levels 2000 1250 750 W Width 69 cm Depth 18 5 cm Height 42 cm Weight 3 3 kg Voltage 220 240 V Isolat...

Page 8: ...ve consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product pleas...

Reviews: