Page 1: ...8 14 ADL 3018 ADL 2012 14 ADL 2012 INSTRUCCIONES DE INSTALACIÓN Y USO INSTALLATION INSTRUCTIONS AND USER GUIDE Lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez Please read these instructions before installing or using this appliance for the first time ...

Page 2: ...do utilizando un programador La instalación del aparato debe realizarse de acuerdo con la legislación eléctrica vigente La instalación o reinstalación y la puesta en servicio debe ser realizada por un instalador eléctrico cualificado Es imprescindible que el aparato esté conectado a una buena toma de tierra Después del montaje vigilar la primera carga hasta verificar la interrupción de la misma po...

Page 3: ...siguientes pasos 1 Elija el emplazamiento del acumulador teniendo en cuenta las distancias entre él y los muebles o cortinas de su entorno Es necesario mantener una distancia libre de 50 cm para asegurar una buena circulación del aire 2 Abra el embalaje por el lugar indicado Retire la caja de accesorios que contiene tornillos y tacos resistencias de acumulación y elementos de sujeción a la pared C...

Page 4: ...lador al dispositivo antivuelco del paso 3 Compruebe que el acumulador queda separado 25 mm de la pared tanto en la parte superior como en la parte inferior 6 Quite los tornillos que sujetan el panel de cierre interior y retírelo ATENCIÓN En la parte posterior de esta chapa se encuentra adherido un delicado panel de aislamiento MICROTHERM se debe manejar con extraordinario cuidado procure no tocar...

Page 5: ...el acumulador 11 Vuelva a montar el panel de cierre interno solapando la parte inferior Si el montaje de los ladrillos ha sido correcto no encontrará ninguna dificultad 12 Coloque el panel frontal primero colgando el mismo de la V existente en la parte superior y colocando los dos tornillos de la parte inferior 13 Finalmente fije la rejilla con los cuatro tornillos INSTALACIÓN DEL TERMOSTATO ELECT...

Page 6: ...ministro CON TELEMANDO está disponible Por favor consulte las instrucciones específicas de los dispositivos que finalmente sean utilizados Durante los primeros ciclos de carga es posible que surjan olores Se recomienda ventilar las habitaciones hasta que estos desaparezcan 4 MANTENIMIENTO Este acumulador de calor una vez puesto en servicio no necesita ningún tipo de mantenimiento especial El polvo...

Page 7: ...installed just below an electrical socket The appliance must be installed in such a way that it is impossible for anyone using a bath or shower to touch the controls The nominal charging time of this storage heater is indicated on its rating plate and must be controlled by means of a programmer The installation must be carried out in accordance with the current electrical regulations This applianc...

Page 8: ...the controlled storage fan heater 1 Chose the right place to install the heater considering the minimum distances between heater and other objects It is needed a minimum distance of 50 cm to assure a good heat delivery 2 Open the carton box by the indicated side and remove the box containing the accessories electrical elements and parts to fix to the wall Turn upside down the box so the heater sta...

Page 9: ...r side Check the heater is separated 25mm from the wall at the top and bottom of the heater Fig 2 Fit and screw the appliance to the anti tilt device 6 Remove the inner front panel WARNING Warning At the other side of this part there is a breakable panel of thermal isolation It must be handle with care Avoid touching it 7 Place a row of storage bricks carefully with the flat side heading the botto...

Page 10: ...all connections are correct and that no connection is damaged Do not leave any remaining wire inside the heater 11 Refit the inner front panel If the bricks have been fitted correctly you will find no difficulty during this action 12 Attach the front panel by hanging i ton the V in the upper part and securing it at the bottom with the two screws 13 Finally fit the outlet grill with the four screws...

Page 11: ... remote thermostat During the first cycles some odors are possible in this case ventilate the room until they disappear 4 MAINTENANCE OF YOUR STORAGE HEATER This controlled storage fan heater does not need any special care Dust accumulated on the heater surface can be removed using a wet cloth when the controlled storage fan heater is cold Do not use dissolvents or abrasive products Night storage ...

Page 12: ... product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inapp...