Specifications
The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.
Problem
Possible cause
Solution
Burner won’t light
• Tank is frosted over
• Blockage in orifice
• Control knob is not in ON
position
• Wait until the tank warms up
and is defrosted
• Clear blockage
• Turn control knob to ON
Burner flame is low
• Gas pressure is low
• Outdoor temperature is
less than 4ºC and tank is
less than 1/4 full
• Control knob fully ON
• Turn tank valve OFF and
replace tank
• Use a full tank
• Check burner and orifices for
blockage
Carbon build-up
Thick black smoke
• Dirt or film on reflector
and burner screen
• Blockage in burner
• Clean reflector and burner
screen
• Remove blockage and clean
burner inside and outside
Troubleshooting
Technical details:
Appliance category:
3+(28-30/37)
3B/P(30)
3B/P(50)
3B/P(37)
Type of gas:
Butane Propane
Butane,
propane,
their mixture
Butane,
propane, their
mixture
Butane,
propane, their
mixture
Gas pressure:
28 - 30
mbar
37 mbar
30 mbar
50 mbar
37 mbar
Outlet pressure of the
regulator:
30
mbar
37 mba
30 mbar
50 mbar
37 mbar
Thermal power:
13 kW (945 g/h)
Gas Pressure
Main Opening
Opening of Burner
280/300
2,0 mm
0,18
370
1,80 mm
0,18
500
1,80 mm
0,18
0063/21