The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.
Symptoms
Possible reason
Solution
The dehumidifier does
not run.
• Power plug fell out.
• Insert the plug into socket.
• Water tank full of water
or place dat incorrect
position.
• Drain the water tank and
place it back in correctly.
• The ambient temperatur
eis lower than 5 °C or
higher than 32 °C.
• Normal phenomenon.
The dehumidification
function is not effective.
• Room temperature or
humiditiy too low.
• In dry seasons the
dehumidification ability will
reduce.
• Air outlet and inlet
blocked.
• Clean up the object block the
air outlet and inlet.
Air is not blown out.
• Air filter blocked.
• Clean the air strainer.
Noise is abnormal
during operation.
• Appliance placed
improperly so that i tis
inclined or unstable.
• Place the appliance on a firm
level place.
• Air strainer blocked.
• Clean the air strainer.
• „Tittering“ sound.
• The flowing sound of
refrigerant, a normal
phenomenon.
Water leakage
• Connection of drainage
pipe becomes loose.
• Fasten drainage pipe.
• Drainage system is
blocked.
• Remove obstacles and
straighten out the waterpipe.
Frosting occurs
• The ambient temperature
is low and i tis in the state
of waiting to defrost.
• It is a normal phenomenon
and the appliance has the
automatic defrosting function.
Troubleshooting