background image

DE 

 

 

Page 

9

 of 

19   

 

 

GB

 

VI. PUFFER FÜR HAUSHALT-HEI

ß

WASSER   

 

 

 

 

 

 

 

 

 

 

 

VI. BUFFERS FOR DHW.

 

 

 

 

 

EV 2000

 

EV 1500

 

EV 1000 

EV 750 

Nominell Volumen 

Total capacity (EN 12897) 

І 

2000 

1500 

1000 

750 

Volumen reell 

Actual capacity (EN 12897) 

l

 

1916

 

1492

 

977 

755 

Isolation

 

Insulation 

mm

 

“Soft” PU 100

 

“Soft” PU 100

 

“Soft” PU 100 

“Soft” PU 100 

Max. Betriebstemperatur 

Maximum operational temperature  T°C

 

95

 

95

 

95

 

95

 

Max. Druck

 

Max. pressure of water tank 

MPa

 

0.8

 

0.8

 

0.8

 

0.8

 

Nominell Betriebsdruck 

Nominal pressure of water tank 

 

0.6 

0.6 

0.6 

0.6 

Positionen für Thermosonden 

Thermopockets 

pcs.

 

2

 

2

 

Nettogewicht

 

Weight 

kg

 

388

 

338

 

211 

196 

 
 

 

750L 

1000L 

1500L 

2000L 

 

351  

354 

 

1767 

1927  

 

1051  

1132 

 

1665 

1827  

 

1502  

1383 

 

1167 

1287  

 

1592  

1475 

 

467 

497  

 

1750 

1895 

 

2193  

2399  

 

1857 

2002 

 

2061  

2263  

 

80  

80 

 

1750 

 

1915 

 

 

272  

272 

 

1250 

 

1370 

 

 

1094  

1174 

 

1080 

 

1141 

 

 

1273  

1273 

 

367 

 

397 

 

 

1512  

1654 

 

90 

 

90 

 

 

1700 

1846 

 

2214 

 

2412 

 

ØD 

 

790  

850 

 

1000 

 

1100 

 

ØC 

 

990  

1050 

 

1200 

 

1300 

 

 
 
 
 
 
 
 

Summary of Contents for EV S 800

Page 1: ...SIE DIE ANWEISUNG VOR DER MONTAGE UND VOR DER INBETRIEBNAHME DES GER TS BEWAHREN SIE SORGF LTIG DAS DOKUMENT WATER HEATERS WITH INDIRECT HEATING WITH ONE HEAT EXCHANGER V S 800 1000 1500 2000 WATER H...

Page 2: ...en in bereinstimmung mit der vorliegenden Anweisung Dear Clients The instruction manual and the technical description are prepared in order to acquaint you with the product and the conditions of prope...

Page 3: ...f llt die Ger tsgarantie aus un der Hersteller tr gt keine Verantwortung bei einem unnormalen Ger tsbetrieb I INTENDED USE The appliance is intended to supply hot water to households equipped with a...

Page 4: ...90 C 60 80 C 50 70 C 50 60 C Exchanged power of HE S2 in continuous mood 70 90 C 60 80 C 50 70 C 50 60 C kW 117 83 51 24 120 95 68 51 72 50 30 17 87 57 36 20 Max Durchflu menge Warmwasser mit T35 C S1...

Page 5: ...DE Page 5 of 19 GB IV BOILER TYP 750 1000 DIMENSIONEN IV OVERALL DIMENSIONS TYPE 750 1000L V X S 750 1000 V X X S2 750 1000...

Page 6: ...000 R Eingang Rezirkulation Recirculation G F TS1 Thermosensor 1 Thermo pocket1 G F TS2 Thermosensor 2 Thermo pocket 2 G F EE elektrisches Heizger t Electric heating element G 1 F T Thermometer Thermo...

Page 7: ...DE Page 7 of 19 GB V BOILER TYP 1500 2000 DIMENSIONEN V OVERALL DIMENSIONS TYPE 1500 2000L V X S 1500 2000 V X X S2 1500 2000...

Page 8: ...0 R Eingang Rezirkulation Recirculation G 1 F TS1 Thermosensor 1 Thermo pocket1 G F TS2 Thermosensor 2 Thermo pocket 2 G F EE elektrisches Heizger t Electric heating element G 1 F T Thermometer Thermo...

Page 9: ...T C 95 95 95 95 Max Druck Max pressure of water tank MPa 0 8 0 8 0 8 0 8 Nominell Betriebsdruck Nominal pressure of water tank 0 6 0 6 0 6 0 6 Positionen f r Thermosonden Thermopockets pcs 2 2 3 3 Net...

Page 10: ...DE Page 10 of 19 GB EV 750 EV1000 EV1500 EV2000...

Page 11: ...2 G F G F TS3 Thermosensor 3 Thermo pocket 3 G F EE elektrisches Heizger t Electric heating element G 1 F G 1 F T Thermometer Thermometer G F G F TR Thermoregler Thermoregulator G F G F CW Eingang Kal...

Page 12: ...antel soll bei dieser Temperatur mindestens 1 Stunde temperiert sein Die Isolation wird gem Fig 8 montiert Nachdem der Zippverschluss zugemacht ist wird die obere Isolation montiert und darauf die Kun...

Page 13: ...DE Page 13 of 19 GB Fig 8...

Page 14: ...n Absperrhahn beim Eingang des Kaltwassers zumachen ffnen Sie den Warmwasserhahn des weitestgelegenen Mischhahn ffnen Sie den Hahn 8 f r das Ausgie en des Wassers aus dem Boiler Falls in der Anlage 3...

Page 15: ...g des Ger ts Unter der Dr nagen ffnung des Sicherheitsventils soll man ein Rohr montieren das an die Abwasserkanalisation oder an ein spezielles Abwassersystem angeschlossen werden muss Das Rohr muss...

Page 16: ...DE Page 16 of 19 GB Fig 7 Fig 6...

Page 17: ...ist in Gebiete mit stark Kalkwasser soll es von dem gesammelten Kalkstein gereinigt werden Diese Dienstleistung ist kein Gegenstand des Garantieservice VIII PROTECTION AGAINST CORROSION MAGNESIUM ANO...

Page 18: ...ter commences to flow from the valve s drainage opening this is a signal of malfunction and the appliance s use must be discontinued This appliance is not intended for use by persons including childre...

Page 19: ...50 600 0 10 20 30 40 50 60 70 80 90 100 Pressure drop mBar Flow rate l min EV 13 7 S2 1000 LOWER HE and EV 13S 1000 0 50 100 150 200 250 300 350 400 0 10 20 30 40 50 60 70 Pressure drop mBar Flow Rate...

Reviews: