Page. 25
LM P RS485 Data Logger
6.5
UPDR
(U
PDATE
D
ISPLAY
R
EFRESH
R
ATE
)
➢
Normally display refresh rate is 1 reading / second. In case the user wants to
increase the display refresh rate, “
UPDR
” option is provided.
➢
To set the refresh rate follow the procedure shown in figure 20.
6.6
PSEN
(P
ASSWORD
E
NABLE
)
➢
For accessing the main menu if the user wants to enable the password
authentication, it can be done using the procedure shown in figure 21.
➢
If user selects “
Yes
” option, then password authentication will be enabled for main
menu.
➢
Main menu will be accessed only after entering the correct password.
➢
If user selects “
NO
” option, then password authentication will be disabled for main
menu.
updr
rfrt
0
1 to 99
SAvE
Press up key to increment and
down key to decrement value
Figure 20 UPDR (Update Display Refresh Rate)
Figure 21 PSEN (Password Enable)
PSEN
yes
no
0
conf
conf
SAvE
SAvE
Summary of Contents for LM Pro 63 Series