MATERIAL CURRENTLY LOADED TO 
SPREAD:000000,

 Job #000007,
 Material #000001,
 Name = UREA-1     ,
 DENSITY = 00750 KG/M3,
 RATE = 01000 KG/HA,
 WIDTH = 02400 CM,
 SPINNER RPM = 000000 RPM,
 DOOR OPENING = 000100 MM,
,
,
GENERAL SYSTEM DATA:,
Run Hold mode = TWIN FLOOR ,
Spreader Setup as Twin Floor,
Firmware Version = SPREADER TWIN 43,
wheel_circumference = 000830,
speedo_debounce_limit = 000020,
run_hold_sensor = 000004,
drill_width = 02400,
backlight_mode = 000001,
unit_type = 000001,
lcd_contrast = 000023,
PWM_Enabled = 000000,
motor_1_connected = 000000,
motor_2_connected = 000000,
drill_wheel_pulse_rev = 000003,
Reference_speed = 000004,
reference_rpm = 000005,
machine_model = 000050,
speed_hours_moving = 000337,
speed_hours_run_stopped = 000093,
speed_hours_hold_moving = 000300,
speed_hours_stopped = 000704,
Support number = 0211535759 ,
,
,
SPREADER SETUP VARIABLES:,
spreader_material_density = 00750,
spreader_rate = 01000,
drill_width = 02400,
shaft_1_rpm_limit = 000000,
spreader_door_opening = 000100,
spreader_floor_width = 000727,
spreader_gearbox_ratio = 000122,
speedo_pulse_count_per_distance = 000001,
spreader_spinner_rpm_dump_mode = 000123,
shaft_1_rev_pulse = 000012,
shaft_2_rev_pulse = 000010,
spinner_stopped_pwm = 010000,
chain_stopped_pwm = 009386,
shaft_update_time = 000001,
spinner_motor_pwm_update_rate = 000002,
chain_motor_pwm_update_rate = 000002,
max chain motor rpm = 000250,
max spinner motor rpm = 001200,
,
,
Variables to calibrate spreader,
rate correction = 010700,
out put slot area offset = 002260,
floor_factor = 023609,
,
,
PRODUCT SETTINGS:,
,
 Material #000001,
 Name = UREA-1     ,
 DENSITY = 00750 KG/M3,
 RATE = 01000 KG/HA,
 WIDTH = 02400 CM,
 SPINNER RPM = 000000 RPM,
 DOOR OPENING = 000100 MM,
,
 Material #000002,
 Name = SUPER-1    ,
 DENSITY = 011200 KG/M3,
 RATE = 002750 KG/HA,
 WIDTH = 024000 CM,
 SPINNER RPM = 000850 RPM,
 DOOR OPENING = 000060 MM,
,
 Material #000003,
 Name = LIME-1     ,
 DENSITY = 00750 KG/M3,
 RATE = 01770 KG/HA,
 WIDTH = 01200 CM,
 SPINNER RPM = 000000 RPM,
 DOOR OPENING = 000060 MM,
,
 Material #000004,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,

 Material #000005,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000006,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000007,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000008,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000009,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000010,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000011,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000012,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,

 Material #000013,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000014,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000015,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000016,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000017,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,

       DOOR OPENING = 000050 MM,

 Material #000018,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000019,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
 Material #000020,
 Name = NAME??     ,
 DENSITY = 007500 KG/M3,
 RATE = 010000 KG/HA,
 WIDTH = 012000 CM,
 SPINNER RPM = 000500 RPM,
 DOOR OPENING = 000050 MM,
,
,
 SPINNER MOTOR RPM-PWM SETTINGS:,
RPM SETTINGS:,
 SPINNER RPM MAX = 001200,
 SPINNER RPM AT 5% OF MAX = 000000,
 SPINNER RPM AT 10% OF MAX = 000000,
 SPINNER RPM AT 15% OF MAX = 000000,
 SPINNER RPM AT 20% OF MAX = 000000,
 SPINNER RPM AT 25% OF MAX = 000000,
 SPINNER RPM AT 30% OF MAX = 000000,
 SPINNER RPM AT 35% OF MAX = 000000,
 SPINNER RPM AT 40% OF MAX = 000000,
 SPINNER RPM AT 45% OF MAX = 000000,
 SPINNER RPM AT 50% OF MAX = 000000,
 SPINNER RPM AT 55% OF MAX = 000000,
 SPINNER RPM AT 60% OF MAX = 000000,
 SPINNER RPM AT 65% OF MAX = 000000,
 SPINNER RPM AT 70% OF MAX = 000000,
 SPINNER RPM AT 75% OF MAX = 000000,
 SPINNER RPM AT 80% OF MAX = 000000,
 SPINNER RPM AT 85% OF MAX = 000000,
 SPINNER RPM AT 90% OF MAX = 000000,
 SPINNER RPM AT 95% OF MAX = 000000,
 SPINNER RPM AT 100% OF MAX = 000000,
PWM SETTINGS:,
 SPINNER PWM SET FOR 0% of MAX SPINNER 

RPM = 010000,

 SPINNER PWM SET FOR 5% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 10% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 15% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 20% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 25% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 30% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 35% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 40% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 45% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 50% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 55% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 60% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 65% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 70% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 75% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 80% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 85% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 90% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 95% of MAX SPINNER 

RPM = 000000,

 SPINNER PWM SET FOR 100% of MAX SPINNER 

RPM = 000000,

,
,
 CHAIN MOTOR RPM-PWM SETTINGS:,
RPM SETTINGS:,
 CHAIN RPM MAX = 000250,
 CHAIN RPM AT 5% OF MAX = 000012,
 CHAIN RPM AT 10% OF MAX = 000024,
 CHAIN RPM AT 15% OF MAX = 000036,
 CHAIN RPM AT 20% OF MAX = 000048,
 CHAIN RPM AT 25% OF MAX = 000060,
 CHAIN RPM AT 30% OF MAX = 000072,
 CHAIN RPM AT 35% OF MAX = 000084,
 CHAIN RPM AT 40% OF MAX = 000096,

 CHAIN RPM AT 45% OF MAX = 00010

8,

 CHAIN RPM AT 50% OF MAX = 000120,
 CHAIN RPM AT 55% OF MAX = 000132,
 CHAIN RPM AT 60% OF MAX = 000144,
 CHAIN RPM AT 65% OF MAX = 000156,
 CHAIN RPM AT 70% OF MAX = 000168,
 CHAIN RPM AT 75% OF MAX = 000180,
 CHAIN RPM AT 80% OF MAX = 000192,
 CHAIN RPM AT 85% OF MAX = 000204,
 CHAIN RPM AT 90% OF MAX = 000216,
 CHAIN RPM AT 95% OF MAX = 000228,
 CHAIN RPM AT 100% OF MAX = 000240,
PWM SETTINGS:,
 CHAIN PWM SET FOR 0% of MAX CHAIN RPM = 009386,
 CHAIN PWM SET FOR 5% of MAX CHAIN RPM = 008405,
 CHAIN PWM SET FOR 10% of MAX CHAIN RPM = 008310,
 CHAIN PWM SET FOR 15% of MAX CHAIN RPM = 008105,
 CHAIN PWM SET FOR 20% of MAX CHAIN RPM = 007950,
 CHAIN PWM SET FOR 25% of MAX CHAIN RPM = 007785,
 CHAIN PWM SET FOR 30% of MAX CHAIN RPM = 007650,
 CHAIN PWM SET FOR 35% of MAX CHAIN RPM = 007500,
 CHAIN PWM SET FOR 40% of MAX CHAIN RPM = 007340,
 CHAIN PWM SET FOR 45% of MAX CHAIN RPM = 007205,
 CHAIN PWM SET FOR 50% of MAX CHAIN RPM = 007080,
 CHAIN PWM SET FOR 55% of MAX CHAIN RPM = 006930,
 CHAIN PWM SET FOR 60% of MAX CHAIN RPM = 006790,
 CHAIN PWM SET FOR 65% of MAX CHAIN RPM = 006680,
 CHAIN PWM SET FOR 70% of MAX CHAIN RPM = 006545,
 CHAIN PWM SET FOR 75% of MAX CHAIN RPM = 006410,
 CHAIN PWM SET FOR 80% of MAX CHAIN RPM = 006290,
 CHAIN PWM SET FOR 85% of MAX CHAIN RPM = 006195,
 CHAIN PWM SET FOR 90% of MAX CHAIN RPM = 006125,
 CHAIN PWM SET FOR 95% of MAX CHAIN RPM = 005995,
 CHAIN PWM SET FOR 100% of MAX CHAIN RPM = 

005955,

,
,
RATE DISPLAY LOCK SETTINGS:,
 RATE 0    TO 100KG:   0    RPM,
 RATE 100  TO 200KG:   10   RPM,
 RATE 200  TO 400KG:   20   RPM,
 RATE 400  TO 600KG:   30   RPM,
 RATE 600  TO 800KG:   40   RPM,
 RATE 800  TO 1000KG:  50   RPM,
 RATE 1000 TO 1200KG:  50   RPM,
 RATE 1200 TO 1400KG:  70   RPM,
 RATE 1400 TO 1600KG:  80   RPM,
 RATE 1600 TO 1800KG:  90   RPM,
 RATE 1800 TO 2000KG:  100  RPM,
 RATE 2000 TO 2200KG:  100  RPM,
 RATE 2200 TO 2400KG:  100  RPM,
 RATE 2400 TO 2600KG:  100  RPM,
 RATE 2600 TO 2800KG:  100  RPM,
 RATE 2800 TO 3000KG:  100  RPM,
 RATE 3000 TO 3200KG:  100  RPM,
 RATE 3200 TO 3400KG:  100  RPM,
 RATE 3400 TO 3600KG:  100  RPM,
 RATE 3600 TO 3800KG:  100  RPM,
 RATE 3800 TO 4000KG:  100  RPM,
 RATE 4000 TO ANY KG:  100  RPM,
 END

Summary of Contents for FIELD MATE

Page 1: ...www areameters com Ver 1 0 Page 1 USER MANUAL Spreader Rate Control Users Guide Installation Manual...

Page 2: ...heel that is not subject to slip or spin during the Spreading Wheel pulse distance and spreading width should corectly entered into to monitor HOLD signal will flash when the spreader is not out putti...

Page 3: ...MATERIAL DENSITY DOOR OPEN measurement SPREADING RATE The FieldMate will compute the chain motor rpm to achieve the desired rate based on the 3 information sets entered above ELECTRICAL SPECIFICATIONS...

Page 4: ...multi functional It can A Reset set the current job totals B Shut down the alarm when the alarm is sounding eg when low seed sensor has triggered C Allows the meter to switch between auto and manual...

Page 5: ...rn on the oil valve using the control valve switch mounted in cab from the FieldMate wiring loom 3 At power up one of the following screens are displayed One screen is a HOLD screen the other screen i...

Page 6: ...Page 6...

Page 7: ...ly occur when this switch is in the SPREAD Position and the Spreader speed is above 1 km hour When in spreading mode the main screen will display the working rate and the state of the chain motors and...

Page 8: ...the REPORT screen quick press the power button to enter the report display screens Spreading information reported Area Distance spreading and not spreading Weight of material spread Time spreading to...

Page 9: ...nne is measure out to test spreader output calibration Note 3 If the Spreader stops at 1 tonne but with 100kg of material left in the spreader then this is concidered a 10 over weighing To fix reduce...

Page 10: ...power button Or the chain motors are stopped Stop the chain motors by holding down the 5 or 6buttons Chain RPM during DUMP MODE Hold the 5or 6buttons to achieve the desired RPM Speed of the Spinner in...

Page 11: ...plug into the spreader 12 pin plug These cables and sensors should be factory connected INSTALLATION Set display contrast Spreading width Speed sensor debounce Typical set 20 Set to Single or double...

Page 12: ...current job Displays the Product name for the current job for the material being spread Number for spinner pulses that occur for 1 rev of the spinner motor Number for chain pulses that occur for 1 re...

Page 13: ...ner when it is just about to start moving Helps with fast starting the motors PWM setting of the chain when it is just about to start moving Helps with fast starting the motors Name of this Spreader D...

Page 14: ...Turn unit on with power button Step 2 Observe main screen Single floor screen Speed The system is in hold both chains motors are off In this HOLD mode the Rate and material spread info are displayed S...

Page 15: ...t will save all totals and display the company logo 2 LCD will go blank unit is off When unit is off hold down or quick press the ON button The following information is displayed on screen 1 Job Model...

Page 16: ...CT hold 5or6 to select the job This job will be the current Job that work is logged to Date and Time renewed Job Totals and Job Name remain untouched Reset a JOB 1 In Main Menu scroll to JOB 2 Quick P...

Page 17: ...rrent job DISTANCE SUB Distance travelled in HOLD mode for the current job DISTANCE TOTAL Total distance travelled in HOLD and RUN mode for the current job 4 Use the 6 key if the Run Hold Mode is Keys...

Page 18: ...for the current job PRODUCT Name of product for the current job SPINNER PULSE Number of Spinner pulses for 1 rev of the Spinner motor CHAIN PULSE Number of Chain pulses for 1 rev of the Chain motor CH...

Page 19: ...tage level Reflects run hold state in twin floor confiuration Screen 6 Software error detection Should be all 0 PWR is the number of power ups that the meter has had BOD may get counts this is a low p...

Page 20: ...b number name Screen 2 Area worked in RUN mode Screen 3 Distance travelled in RUN mode Distance travelled in HOLD mode Screen 4 Weight output Screen 5 Time moving in RUN mode Time stopped in RUN mode...

Page 21: ...ate area meter is connected When this occurs the DOWN LOAD READY button is displayed 4 With the FM DRILL PRO connected to the computer Press the DOWNLOAD READY button The data is instantly returned fr...

Page 22: ...03 4348 KM HOLD DIST 00000 4473 KM TIME_RUN_MOVING 0 33 Hour Min TIME_RUN_STOPPED 0 58 Hour Min TIME_HOLD_MOVING 0 03 Hour Min TIME_HOLD_STOPPED 1 06 Hour Min TIME_TOTAL 2 41 Hour Min TICK_RUN 004334...

Page 23: ...ITY 007500 KG M3 RATE 010000 KG HA WIDTH 012000 CM SPINNER RPM 000500 RPM DOOR OPENING 000050 MM SPINNER MOTOR RPM PWM SETTINGS RPM SETTINGS SPINNER RPM MAX 001200 SPINNER RPM AT 5 OF MAX 000000 SPINN...

Page 24: ...Now CHAIN UPDATE 111 SPIN UPDATE JOB SPIN RPM MAX CHAIN RPM MAX SPIN RPM DOOR OPENING 1111 SPREAD RATE PRODUCT SPINNER PULSE CHAIN PULSE CHAIN 2 PULSE 11111 FLOOR WIDTH DENSITY BOX RATIO SPEED PULSE D...

Page 25: ...emperature improper power application damage resulting from acts of war or any damage incurred due to acts of nature salt or fresh water immersion or spray or improper or unauthorized repair Freight c...

Page 26: ...Meter computer have read the above Warranty and Limitations of liability Agreement and agree to the conditions and limitations as stated above Unit Serial Number Start Date of Agreement Purchaser Comp...

Reviews: