16
-
8.2 Discharging NiCd/NiMH battery
8.3 Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery
Set discharge current on the left and final voltage on the right. The discharge current ranges
from 0.1 to 5.0A and the final voltage ranges from 0.1 to 25.0V). To start the process, press
Start /Enter
key more than 3 seconds.
The screen displays the current state of discharge. You can alter the discharge current by
pressing
Start/Enter
key during the process. Once you change the current value, store it by
pressing
Start/Enter
button again.
To stop discharging press
Batt type/Stop
key once. The audible sound indicated you at the
end of process.
Set the sequence on the left and the number of cycle on the right. You can use this function
for balancing, refreshing and break-in the battery. To avoid rising temperture of the battery,
there will a brief cool-off period that already fixed at 'User setting' after each charge and
discharge process. The cycling number ranges from 1 to 5.
To stop the process, press
Batt type/Stop
key once.
You can change the discharge or charge current by pressing
Start/Enter
key once during the
process. The audible sound indicates you the end of process.
At the end of the process, you can see charged or discharged electric capacities of the battery
at each cyclic process.
By pressing
INC
or
DEC
button, the screen shows the result of each cycle in order.