![G-Scale Graphics RailBoss Plus Operation And Installation Manual Download Page 20](http://html1.mh-extra.com/html/g-scale-graphics/railboss-plus/railboss-plus_operation-and-installation-manual_3082107020.webp)
Page 20
Option
Parameter 0 -
Station Stop
Dwell Time
1
15 secs
2
30 secs [factory setting]
3
45 secs
4
60 secs
Option
Parameter 1 -
Station Stop
Accel/Decel Time
1
Fastest
2
Faster
3
[factory setting]
5
Slowest
4
Slower
Option
Parameter 2 -
Whistle Operation
from Reed Sw
1
100% (Always triggers via track magnet)
[factory setting]
2
75%
3
50%
4
25%
5
0% (Disabled)
Option
Parameter 4 -
Throttle Momentum
1
Fastest Response (Off) - (factory setting)
2
Faster
3
Medium
4
Slower
5
Slowest
Option
Parameter 5 -
Direction Control
1
Forward / Reverse (No Neutral) [factory setting]
2
Forward / Neutral / Reverse
Option
Parameter 3 -
Station Stops & Bell
from Reed Sw
1
100% (Always triggers) / Trolley mode
[factory setting]
2
75%
3
50%
4
25%
2.4GHZ RailBoss Plus
DIP Switch Programming
Option
Parameter 6 -
No. of Lithium Battery Cells
(3.7V ea.)
1
Disable Low Battery Warning [factory setting]
2
2 Cells, 7.4V
3
3 Cells, 11.1V
4
4 Cells, 14.8V
5
5 Cells, 18.5V
6
6 Cells, 22.2V
7
7 Cells, 25.9V
Option
Parameter 7 -
Low Battery Warning Voltage
1
Lowest Voltage, least run-time after warning
2
3
4
5
[Factory Setting]
6
7
Nominal Voltage, most run-time after warning
2.4GHZ RailBoss Plus