Controlling The Temperature

The Microprocessor will scan the temperature parameters every 3 minutes, when the temperature
goes outside of the temperature parameters this will generate a text alarm sent to the users indicating
the current temperature and turn on relay 1.

When the temperature returns into the temperature parameters, a text will be generated to let users
now temperature is normal, and relay 1 will be turned off

Text Commands

#

+

09*20

#

  This will save the parameter settings for plus 9 degrees to plus 20 degrees

#

-

10*20

#

 

This will save the parameter settings for minus 10 degrees to minus 20 degrees

*NOTE YOU CANNOT MIX MINUS AND PLUS TEMPERATURES - PLEASE USE + OR - SYMBOL

#

START

#

 will start the temperature reading / temperature alarm

#

STOP

#

  will stop the temperature reading / temperature alarm

*Note In the event of a power loss the unit will remember if it was in stop or start mode

#

TEMP

#

  at any time you can text this to get a temperature reading

Summary of Contents for GSM Auto Dialler Plus

Page 1: ...GSM 4G AUTO DIALLER PLUS Control and Monitoring from your mobile phone Page 1 MODEL 4GAD...

Page 2: ...Deleting Contact Numbers 7 How to Store Input Text Messages How to Set Phone Call Alerts and Text Messages 8 Activating the Output Relays 9 Activating Inputs 10 Mains Failure Monitoring Battery Back U...

Page 3: ...hz 4G Bands B1 B5 B7 B8 B12 B14 B18 B20 B25 B26 B28 B66 B71 Power Supply Voltage 9 24 volts DC Current Used in Standby Mode 35 Milliamps Max Current Up to 2 Amps Standard 2G 3G 4G Simcard No landline...

Page 4: ...e red LED indicates that the battery is in charging mode Battery Switch push on to turn battery backup on battery only charges with battery switch on Dipswitch The dialler can work on 2G 3G 4G network...

Page 5: ...4502 Giff Gaff call 1626 EE send the text message command VM OFF to 150 ENSURE THE UNIT IS POWERED DOWN AND BATTERY TURNED OFF BEFORE INSERTING THE SIMCARD 1 Slide back the sim door and lift it up 2 S...

Page 6: ...mbers please follow this example PH1 07712345678 Stores the mobile landline phone number as contact no 1 PH2 01903123456 Stores the mobile landline phone number as contact no 2 PH3 07123456789 Stores...

Page 7: ...s INPUT ACTIVATED Note your can only use a maximum of 30 characters including spaces for you customised message Telephone Call Alerts The auto dialler can be programmed to send you a telephone call af...

Page 8: ...n please send the SMS AUTO ON this will turn the AUTO function on for relay 2 only AUTO OFF this will turn the AUTO function off for relay 2 only default setting is off Activation by SMS Text Message...

Page 9: ...RED ALARM OFF This will deactivate the alarm Pulling the input to the ground will mean you will receive NO notifications Using the Inputs Inputs 1 2 3 Automatically Reset Inputs 1 2 3are triggered by...

Page 10: ...will need to be recharged by connecting 12 volts back to the power input NOTE The battery will only work when the battery is switched on If you do not switch the battery switch on then the battery ba...

Page 11: ...now temperature is normal and relay 1 will be turned off Text Commands 09 20 This will save the parameter settings for plus 9 degrees to plus 20 degrees 10 20 This will save the parameter settings for...

Page 12: ...Page 11 Quick Reference...

Page 13: ...re commissioning please ensure the signal strength is sufficient by sending the text message STATUS We strongly recommend you need a score of at least 10 Also try the signal using both the 2G 3G 4G vi...