Status Report
It is possible to obtain a relay status report at any time. This will give you the position of
the relays.
#
STATUS
#
To get relay status report (this will only work if you have Text replies on)
IMPORTANT - PLEASE READ
The unit has a “sim active” function which monitors the activity on the simcard. If it has
been inactive for 6 weeks, it will send an automatic text to a pre-recorded number. This
will then eliminate the problem of your sim getting shut down if they are unused for 3
months.
New SIM cards will need registering before they can be used. Full details of how this is
done can normally be found in the SIM card pack. It will normally require that the SIM card
is inserted into a mobile phone, a number dialled and instructions followed. While the SIM
is in the mobile phone it would be a good time to disable any PIN codes, call diverts, ring
back and disable features such as voicemail and text alerts. Details of how to do this can
be found on the SIM card provider’s web site or by calling their customer services. Please
use one of the following SIM card providers -Vodafone, TMobile, O2 or Orange.
Note
Currently not suitable with the network provider “three”
Relay Memory
In the event of power loss the switch can remember the relay positions for when the power
has
been restored, please send the text as follows:
#
MEMORY
=
ON
#
The unit will remember relay status in event of power failure
#
MEMORY
=
OFF
#
The unit will not remember relay status and power on with both relays
set to off
The default setting is Relay Memory OFF
Relay State report is the status of BOTH relays
REL 1 OFF
=
REL 2 OFF
REL 1 ON
=
REL 2 OFF
REL 1 OFF
=
REL 2 ON
REL 1 ON
=
REL 2 ON
Page 6
Timer Mode: Relay 2 only
It is possible to turn relay 2 ON for a period of time, 1 minute to a maximum 999 minutes.
Send the following command followed by the number of minutes you require
#
MIN
=
Example
#
MIN
=
001
#
This will turn on the relay for 1 minute.
Example
#
MIN
=
060
#
This will turn on the relay for 60 minutes.
Example
#
MIN
=
120
#
This will turn on the relay for 120 minutes.
The maximum number of minutes is 999.
You will receive a text acknowledgment “TIMER SET”
The timer will stay on for the preset time and then turn itself off. If you wish to cancel the
timer before the preset time has expired you can do this by texting
#
MIN
=
000
#
this will
cancel the time.
www.gsm-activate.co.uk