background image

Page 7

How to use the 2G/3G Wireless Beam Alarm

Once you have positioned the beams, installed the simcard and  programmed the
numbers the system is ready to be used.

The GSM Wireless Beam Alarm has two modes, alarm mode and auto mode. Alarm mode
you have to arm the alarm manually each time when required. Auto mode, the alarm is
always armed. You should choose which mode is more suitable to your application.

These modes are selected by sending the following text messages

#

mode

=

1

#

 

Alarm Mode (default)

#

mode

=

2

#

 

Auto Mode

Mode 1 - Alarm Mode: 

#

mode

=

1

#

Alarm mode is the default mode. You need to set the alarm to ON before it detects
movement and sends an alarm message.

To set the alarm to ON you will need to send the text message

#

ALARM

=

ON

This will activate the alarm

#

ALARM

=

OFF

This will deactivate the alarm

It is important to remember that when the alarm has been triggered you will need to reset
the alarm by sending another text message 

#

ALARM

=

ON

#

 to reactivate the alarm.

Mode 2 - Auto Mode: 

#

mode

=

2

#

The alarm is always armed and will trigger when movement is detected. It will
automatically reset back into armed mode after 20 seconds when no movement is

How to use the Relay Output

Dipswitch 2 = OFF 

(ref page 3)

The Wireless Beam Alarm has a  amp relay output which can be used to switch on
external electric devices such as lighting, sirens etc

By texting the unit you can turn the relay ON or OFF. Below are examples on how to do
this.

#

REL

=

ON

This will turn ON the relay output

#

REL

=

OFF

This will turn OFF the relay output

After each operation the unit will reply with a status report of “REL ON/OFF”

Dipswitch 2 = ON 

(ref page 3)

The relay can also be set up to pulse for 20 seconds when the inputs have been
triggered. To activate this mode you need to set DIPSWITCH 2 to the ON position.

This can be used to trigger a siren or reset other equipment.

Summary of Contents for 2G RF BEAM

Page 1: ...PAGE 1 MODEL RF BEAM 2G 3G GSM Wireless Beam Alarm www gsm activate co uk ...

Page 2: ...ratures GSM Module Specification GSM Frequency Quadband freq 850 900 1800 1900 3G Model 2100 Mhz Power Supply Voltage 9 24 volts DC 1 Amp Min Current used in standby mode 60mA Max IP65 Enclosure rating for outside installation 2 Amp Relay Output Micro 2G or 3G Simcard No land line required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 40...

Page 3: ...inwards Please see picture above Signal Strength To help make sure you place the unit in a suitable position you can text the unit to see how much signal strength the detector is receiving by sending the text command SIGNAL The detector will perform a test on the signal strength You will receive a text telling you a signal strength score of between 0 up to 30 We strongly recommend that you place t...

Page 4: ...d this as a text message to the simcard number of your unit for the second contact 3 07123456789 Then send this as a text message to the simcard number of your unit for the third contact If you wish to cancel a number please follow this example Example HASH 1 2 or 3 EQUALS DELETE HASH 1 DELETE Then send this as a text message to the simcard number in your unit PLEASE NOTE Please only send one text...

Page 5: ...or your customised message Telephone Call Alerts The Wireless Beam Alarm can be programmed to send you a call after each text alarm has been sent You will receive approximately three ring tones The unit will then hang up This is to avoid any call charges being incurred To set the alerts to ON please send the text message CALL OFF The unit will reply back with CALL ON To disarm the alerts please se...

Page 6: ...is important to have the correct Power Supply to operate this device successfully You will need a 12 volt 2 Amp supply or 12 volt battery You can purchase both of these from our website www gsm activate co uk 5 Now you have the transmitter and receiver fitted to the location you can carry out alignment You will now need to turn ON the power 6 There are two adjustments left and right and up and dow...

Page 7: ...o remember that when the alarm has been triggered you will need to reset the alarm by sending another text message ALARM ON to reactivate the alarm Mode 2 Auto Mode mode 2 The alarm is always armed and will trigger when movement is detected It will automatically reset back into armed mode after 20 seconds when no movement is How to use the Relay Output Dipswitch 2 OFF ref page 3 The Wireless Beam ...

Page 8: ...d down the pairing button on the RF module for 3 seconds refer to figure 1 4 Trigger the beams by placing your hand between the beams 5 The RF module has a RED LED which will flash when pairing is complete 6 Dipswitch 1 controls the 2G and 3G 7 Dipswitch 2 controls the relay mode PLEASE NOTE The transmitter and receiver will work from a distance of 100 metres outside and 300 metres inside Addition...

Page 9: ...onitoring system Vending machines security protection Pumping stations tanks oil or water levels Buildings and real estate Weather stations River monitoring and flood control Fridges Fish Tanks Farming equipment and security Dipswitch Settings Dipswitch 1 ON 3G Selected OFF 2G Selected Dipswitch 2 ON Pulse Relay 20 seconds OFF Relay off For more technical support please browse the FAQ s on our web...

Reviews: