Electric shock & static protection:

 

 

These moving heads are designed to work and depend on the 
electric shock protection. The moving head should be connected 
with the power supply system. The moving head's ground cable 
should be connected with the ground cable of the power supply 
system. The ground mark of the fixture metal cover should be 
securely connected with the installation bracket. 
 

Connect the main power supply:

 

 

Connecting of the main power supply should be done by a 
professional. 
 

Please check the voltage, frequency data of power supply system 
of the moving head to avoid different voltage or melting.  

 

Please refer to the actual wattage allowed of the moving head's 
lamp. Multiply 1.5 total quantity of the moving head then you could 
get the minimum power loading. If your power cable can't share the 
minimum power supply loading. Do not connect all the moving 
heads  

 

 

3. Lamp replacement

 

 

Lamp Description 

 

      Model 

  

Lamp Description 

  

  

  

  

Philips 

  

Osram 

  

  

  

           600SZ 

MSI 575W HR 

HMI 575W /GS 

  

  

  

  

 6000 K 

1000 Hr 

5600K 

1000 Hr 

  

  

 

 
Lamp Replacement 
 
Warning: 
Disconnect the power supply before replacing the lights. 

 

Open the lamp access panel at the rear of the moving head by undoing the 4 
hand-operated screw .Then you can begin to replace the lamp. Pull out the old 
lamp from the lamp bracket and then plug in the new lamp. Remount the lamp 
bracket and fasten the screw at both sides tightly or the lamp's loose connection 
will result in high tension short circuit or electric discharge which will effect the 
lamp life or damage the PCB board. When replacement is complete, close the 
cover and fasten the screw at both sides tightly. 

 

Summary of Contents for 1200SZ

Page 1: ...www g lites com 1 User Manual MOVING HEAD MODEL 600SZ...

Page 2: ...ly connection control 11 4 2 signal connection 11 4 3 Fixture connection 12 5 Moving Head IP Code Programming 12 6 Moving Head IP Function selection 13 7 Display Menu Map 13 8 DMX Channels Photometric...

Page 3: ...the safety precautions listed below A Read this manual carefully and keep manual near moving head B Follow the safety regulations mentioned in this manual when operating or installing this fixture C W...

Page 4: ...www g lites com 4...

Page 5: ...mitment to continuous products update the company will keep the right to improve this product the information in this menu may be changed without notice Transportation Please be sure to lock the head...

Page 6: ...www g lites com 6...

Page 7: ...to the bottom of the moving head with 4 bolts provided in the package Always make sure that the moving head is anchored firmly to avoid any vibration or fall For safety purposes the moving head shoul...

Page 8: ...face Keep flammable objects at least 1 meter away from fixture Do not light objects closer than 1 meter o Replace fuses only with the specified type and rating o Ambient temperature In order to ensure...

Page 9: ...5 total quantity of the moving head then you could get the minimum power loading If your power cable can t share the minimum power supply loading Do not connect all the moving heads 3 Lamp replacement...

Page 10: ...e of the recharge lamp can not work under the interruption power supply Therefore please let the lamp cool down completely Approx 15 minutes at least Then it s ready to operate again Other wise it wil...

Page 11: ...AM and PHILLIPS is 700 hours the average lift time of other brand is 70 100 hours 4 Power Supply Control 4 1 Power Supply Connection and Control Use a professional plug to connect the moving head and...

Page 12: ...of the fixtures is over 15meter 4 3 Fixture Connection After performing the above instructions and after making sure the moving heads have the appropriate lamps press the power switch to check whethe...

Page 13: ...1 DMX setting address setting d 001 d 512 2 PAN normal anticlockwise 180 degree setting Pa rI PA LE 3 TILT normal anticlockwise setting TI Dn TI Up 4 Extend compress channel setting 16 bit 8 bit 5 PA...

Page 14: ...www g lites com 14...

Page 15: ...4 Pan Coarse 5 Tilt Coarse 5 Tilt Coarse 6 Color Wheel A 6 Color Wheel A 7 Gobo Wheel B 7 Gobo Wheel B 8 Gobo Wheel A 8 Gobo Wheel A 9 Gobo Wheel A Rotation 9 Gobo Wheel A Rotation 10 Iris 10 Iris 11...

Page 16: ...www g lites com 16 8 2 DMX PROTOCOL CHART...

Page 17: ...www g lites com 17...

Page 18: ...www g lites com 18...

Page 19: ...tal GOBO Wheel A outside 28mm inside 22mm Rotating glass GOBO Wheel A outside 28mm inside 21 5mm Fixing GOBO Wheel B outside 28mm inside 20 5mm White outside 28mm inside 23mm The GOBOS can be differen...

Page 20: ...se it to explode If the lamp is accidentally touched clean it immediately with a soft cloth and isopropyl alcohol CH CH0H o Clean the lens and dichroic filters on a regular basis Do not use any type o...

Page 21: ...OR wheel GOBO 8 fixed interchangeable metal gobos white light 6 rotating glass gobos white light all can be custom made Rotating gobos can freely move clockwise or anticlockwise fast or slowly Angles...

Page 22: ...position Precise speed adjustment on horizontal and vertical position INPUT 3 pin or 5 pin in and out DMX 512 signal 18 Channel 16 Bit or 12 Channel 8 Bit SET UP Separate motor debug remote control S...

Page 23: ...www g lites com 23 CONSUMPTION Power Consumption 680 W DIMENSION L470mm W365mm H697mm WEIGHT 43 5 Kg...

Page 24: ...color o Replace the lamp o Clean optics o Re home the fixture Unit is producing unexpected results o Check DMX starting address on the fixture and console match o Verify that the last fixture on the...