13
Battery Wires
Connect 12 v Transformer
Wires to 12-24VAC Terminals
Refer to the “
SL DC2 Circuit Board”
data sheet included with this manual and locate the ‘12-
24VAC’ terminals on the circuit board.
Connect the 12 v transformer wires to the ‘12-24VAC’ terminals on the circuit board. There is
no positive or negative transformer wire and they can connect to either of the two “12-24VAC’
terminalsConnect the battery wires to the battery.
Red
, Positive wire to
Red
battery terminal,
Black / Blue
Negative wire to
Black
battery terminal
Terminal Block
12 v Low Voltage
Transformer Wires
1.5mm Twin Active Low
Voltage Cable
Weather Proof
Enclosure
If the 12 v low voltage transformer wires need to be extended then we recommend you use a ter-
minal block / joiner. Place the terminal block / joiners into a small enclosure for protection and
outdoor installation.
SL DC2 Transformer
Wiring
DIY Automatic Gate Kits
Solar & Low Voltage Specialists
PH 1800 111 930
Red
wire to
Red
battery
terminal
Black / Blue
wire to
Black
battery terminal
Battery Connection
Transformer
12 v Transformer Wires
© 2012 G Force Automatic Gates All Rights Reserved