background image

Page 1

1. Read this manual carefully before installing or using this equipment.

2. This equipment is designed for paint drying applications. Adjust to the correct 

     temperature and check minimum safe distance from the heat source when using. 

     Improper use may cause paint surface damage.

3. Installation and servicing must be performed by a qualified installer or service agency.

4. The system has been designed for easy installation, low operating costs and minimal 

     maintenance. The warranty does not cover lamp tube defects resulting from misuse or 

     improper operation.

5. Disconnect power source when the equipment is not in use for a long time.

6. The light tube should not be perpendicular to the ground when the equipment is in 

     operation. Otherwise, it will shorten the useful life of the light tube.

7. Make sure the cassette plug is tightly connected before using to prevent it from burning.

1. Precaution

Summary of Contents for FY-4CM

Page 1: ...Instruction Manual Our equipment is approved by the following car manufacturers China FY 4CM...

Page 2: ...Contents 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Light Tube Replacement 7 Exploded View 8 Circuit Diagram 1 2 3 4 5 7 8 9 10...

Page 3: ...taller or service agency 4 The system has been designed for easy installation low operating costs and minimal maintenance The warranty does not cover lamp tube defects resulting from misuse or imprope...

Page 4: ...l Input Voltage Input Power Curing Area Temperature Time Setting Light Intensity FY 4 220V 1 phase 50 60Hz 4 1000W 1200 1000mm 35 C 80 C adjustable 0min 99min adjustable 10 100 CM 2 Specifications Pag...

Page 5: ...b Put the column vertically on the top of the base directly engage the screw holes and tighten up using the screws c Connect the support arm with the column for supporting the cassette d Connect the...

Page 6: ...stance adjustment 7 Lamp selector each lamp can be controlled separately 8 Pulse 9 Routine 10 Auto 11 Nearest distance adjustment press this button first then press Button 6 to adjust the nearest dist...

Page 7: ...when the equipment is not in use and keep the equipment securely in place step1 step2 step3 step4 5 min Routine Time Power 7 0 Pulse Time 1 5 min Power 6 0 Routine Time 5 min Power 6 0 Pulse Time 1 5...

Page 8: ...is set to 5 mins and Routine to 10 mins f Press the button Start Stop g Turn off the equipment when the work is completed 3 Pulse Mode a Press the button Auto when the lamp is ready to use to shut do...

Page 9: ...Lamp is not plugged in c Control silicon damaged a Control silicon damaged a Unplugged flat wire in circuit board b Digital display damaged a Switch imbalance b Key board has exclusion a Check light t...

Page 10: ...Remove the screws on the side panel of cassette 3 Remove the screws on the front panel to open it 4 Remove the screws on both ends of the lamp tube so it can be replaced 5 Reverse the steps above afte...

Page 11: ...9 NAME Column Plastic band Top cover Aluminium handle Upper connecting rod Adjustable hand wheel Long bolt Cassette washer NAME Side panel Junction box Cassette Fan cover Cassette handle Spring Lock S...

Page 12: ...Diagram 220V 0V G2 K2 G1 K1 K1 G1 K2 G2 G1 G2 K1 K2 O v e r C u r rent P r o t e c t i o n S w i t c h A C 2 2 0 V 0V 12V 0V 12V 0V 12V P C B B o a r d Control Silicon Power Switch Transformer PCB fo...