background image

IMPORTANT: Your FWE Proofer-Heater is designed to give

maximum performance by using the heat control and the

proof control simultaneously. To achieve the desired results

for various products, it is suggested that you experiment 

with various settings. 

Please see the GENERAL OPERATING INSTRUCTIONS -

PROOF MODE for several examples of simultaneous 

control settings, resulting in relative humidity.

CAUTION:  HOLDING FOOD AT TEMPERATURES 

OF LESS THAN 140°F  MAY BE DANGEROUS.  

TEMPERATURES UNDER 140°F PROMOTE THE GROWTH

OF HARMFUL BACTERIA AND TOXINS IN SOME FOODS.

CONGRATULATIONS...

...and thank you for purchasing an FWE Mobile PROOFER/HEATER
cabinet.  Your unit has been designed and manufactured under rigid
controls to assure you the most efficient service.  It is a full time unit,
and may be used continuously.

Please take a moment to read through this booklet of important 
information pertaining to your cabinet.  By following a routine of 
proper use and care described on the following pages, your cabinet 
will last for many years.

IMPORTANT:  Your Manufacturer Registration Card must be 
returned within 30 days after initial delivery to put warranty into effect.

FWE PROOFER/HEATER CABINETS

REGISTRATION CARD

2

Summary of Contents for ETC-1826-PH Series

Page 1: ...6 SERIES PH BBC SERIES ETC 1826 PH SERIES ETC UA PH SERIES Thermometer Air Temperature HEAT Control Dial Air Temperature Cycling Light Air Moisture Cycling Light Air Moisture PROOF Control Dial with P to Indicate Proof Position Main Power Switch Heat Basin Water Pan ...

Page 2: ... the same versatile cabinet 1 FWE PROOFER HEATER 12 x 20 Water Pan and Heat Basin Heat System Tunnel Control Panel Moisture Drip Trough With Removable Drain Plug Serial Tag and Parts List Uprights and tray slides remove and adjust easily without tools ...

Page 3: ...E THE GROWTH OF HARMFUL BACTERIA AND TOXINS IN SOME FOODS CONGRATULATIONS and thank you for purchasing an FWE Mobile PROOFER HEATER cabinet Your unit has been designed and manufactured under rigid controls to assure you the most efficient service It is a full time unit and may be used continuously Please take a moment to read through this booklet of important information pertaining to your cabinet...

Page 4: ...G FROM THE CORD PLUG WARNING ONLY A QUALIFIED ELECTRICIAN SHOULD ATTEMPT TO REPAIR OR REPLACE ELECTRICAL COMPONENTS OR WIRING BE SURE THAT MODEL IS UNPLUGGED FROM ELECTRICAL SOURCE BEFORE REMOVING CONTROL PANEL PROOFER HEATER CABINET SERIAL AND MODEL NUMBER INSTALLATION UNPACKING ELECTRICAL REQUIREMENTS AND GROUNDING These numbers are found on the nameplate serial tag affixed to the lower back of ...

Page 5: ...ch activates power to the cabinet Your Proofer Heater is equipped with two 2 heating elements and two 2 separate controls which regulate these elements This allows you to set the temperature and humidity needed for the mode holding or proofing you have chosen The control knob marked PROOF is an infinite control 1 7 settings which regulates the amount of warmed moisture in the cabinet A light indic...

Page 6: ...e higher the heat setting the lower the humidity since higher temperatures will cause more rapid evaporation of the moisture EXAMPLE If heat setting is at 100 F and proof setting is at 5 it should result in 96 relative humidity in the interior of the cabinet EXAMPLE If heat setting is at 140 F and proof setting is at 5 it should result in 90 relative humidity in the interior of the cabinet EXAMPLE...

Page 7: ...ASIN shown WITHOUT 12 x 20 pan KEEP HEAT BASIN DRY WATER PAN POSITIONS INTO HEAT BASIN ADD WATER INTO 12 x 20 PAN ONLY NO WATER IN HEAT BASIN ADD HOT WATER TO 12 x 20 PAN Amount of water required in pan is determined by 1 Start up time Less Water Faster Start up 2 Length of proofing time 3 Level of humidity desired 12 x 20 Pan Shown Positioned Into Heat Basin ...

Page 8: ... Tunnel positions into tabs Heat Tunnel WATER PAN IS REMOVABLE AND REPLACEABLE ADDING WATER TO 12 x 20 PAN Heat Tunnel Heat Tunnel Stand 12 x 20 Pan Positioned Into Heat Basin Add HOT WATER to 12 x 20 Pan Add HOT water to 12 x 20 pan with heat tunnel in position Water Pan is positioned into heat basin Amount of water required in pan is determined by 1 Start up time 2 Length of proofing time 3 Leve...

Page 9: ...th small blade screwdriver by turning COUNTER CLOCKWISE 1 4 turn raises temperature approximately 10 F DO NOT REMOVE SET SCREW 3A Plug cabinet into properly grounded electrical outlet 3B Adjust thermostat knob to temperature setting required 3C Turn switch to ON position 3D Have a qualified electrician check power to fuse box 3E Unplug cabinet from electrical source Loosen set screw in thermostat ...

Page 10: ...________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______________________________________________...

Page 11: ...one 1 year except for equipment used in a Correctional Environment Facilities which is warranted for a period of six 6 months This warranty is for normal usage and does not apply to any product or parts thereof that have been misused altered or where Seller s operating instructions or specific voltage is not observed nor shall this warranty apply to defective products or parts resulting from accid...

Page 12: ...to change without notice Printed in USA FWE Parts Department www FWEparts com Phone 815 459 7500 FAX 815 459 7989 WE OFFER SALES AND SERVICE WORLDWIDE Food Warming Equipment Company Inc P O Box 1001 Crystal Lake IL 60039 1001 Manufacturing Facilities 5599 Highway 31 West Portland TN 37148 sales fweco net www FWE com ...