23
Optimum hose sizes
SF2H
Diamètres optimales des tuyaux SF2H
Diámetros óptimos de manguera SF2H
Pipe size/
Diamètre du
tuyau/
Diámetro de
manguera
Total head Hauteur totale Elevación total (m)
Flexible hose
Rigid PVC pipe
15 to 20
20 to 45
15 to 20
20 to 45
Length of
pipe/
Longueur
de tuyau/
Largo de
la tubera
(m)
10
3/4” (19mm)
3/4” (19mm)
3/4” (19mm)
3/4” (19mm)
20
1” (25mm)
3/4” (19mm)
3/4” (19mm)
3/4” (19mm)
30
1” (25mm)
3/4” (19mm)
1” (25mm)
3/4” (19mm)
40
1” (25mm)
1” (25mm)
1” (25mm)
3/4” (19mm)
60
1” 1/4 (32mm)
1” (25mm)
1” (25mm)
1” (25mm)
80
1” 1/4 (32mm)
1” (25mm)
1” 1/4 (32mm)
1” (25mm)
100
1” 1/4 (32mm)
1” (25mm)
1” 1/4 (32mm)
1” (25mm)
200
1” 1/4 (32mm)
1” 1/4 (32mm)
1” 1/4 (32mm)
1” 1/4 (32mm)
300
1” 1/4 (32mm)
1” 1/4 (32mm)
1” 1/4 (32mm)
1” 1/4 (32mm)
400
1” 1/2 (38mm)
1” 1/4 (32mm)
1” 1/2 (38mm)
1” 1/4 (32mm)
600
1” 1/2 (38mm)
1” 1/2 (38mm)
1” 1/2 (38mm)
1” 1/4 (32mm)
800
1” 1/2 (38mm)
1” 1/2 (38mm)
1” 1/2 (38mm)
1” 1/4 (32mm)
Summary of Contents for SF2
Page 4: ...4 c d e f g h i j k a b ...