Document 8K088X04 R5.01
Portable Digital Repeater Programming Guide
Page 59 of 86
Field Name
Options / Units
Description
Notes
Channel
1-64 Channels
Identifies the name of the channel for the
current Analog Code Table
< Prev.CH
1-64
Decrements Channel by 1
Changes the
Analog Code
Table
accordingly.
< Next CH
1-64
Goes to the next channel
Changes the
Analog Code
Table
accordingly.
PL/DPL Code
Table Name
Maximum 10
alphanumeric
characters
Name that identifies the current Analog
Code Table.
< Prev.Tbl
1-64
Decrements Analog Code Table by 1
< Next Tbl
1-64
Goes to the next Analog Code Table
Channels Using
This Table:
Comma separated
list of numbers, 1-64
List of PDR8000 channel number(s) that use
current Analog Code Table.
This field is read
only.
Multi PL/DPL
Enabled
Disabled
Multi PL/DPL
- Multi-coded squelch allows
you to predefine a set of accepted Rx
PL/DPL and associated Tx PL/DPL being
used by repeat calls.
Receiver operation allows PDR8000 to
accept incoming RF signal containing a
specific PL/DPL value as defined by the Rx
PL/DPL field in the first row of Multi-PL/DPL
table. Repeater calls are transmitted using
the Tx PL/DPL field value as defined in first
row of Multi-PL/DPL table.
Receiver operation allows PDR8000 to
accept incoming RF signal containing a
specific PL/DPL value as defined by the Rx
PL/DPL field in all the 14 rows if ‘Enabled’ in
the Multi-PL/DPL table. Repeater calls are
transmitted using the Tx PL/DPL field value
as defined in the Multi-PL/DPL table.