2-4 Power Wiring
2-4 Power Wiring
The unit is supplied to operate at 11-26 VAC / VDC or 90-264VAC.Check
that the installation voltage corresponds with the power rating indicated
on the product label before connecting power to the unit.
90
264 VAC or
11
26 VAC / VDC
~
~
Fuse
Figure 2-4
Power Supply Connections
Figure 2-4
Power Supply Connections
1
2
3
4
5
6
7
8
9
10
This equipment is designed for installation in an enclosure
which provides adequate protection against electric shock. The
enclosure must be connected to earth ground.
Local requirements regarding electrical installation should be rigidly
observed. Consideration should be given to prevent from unauthorized
person access to the power terminals.
Proper sensor installation can eliminate many problems in a control
system. The probe should be placed so that it can detect any
temperature change with minimal thermal lag. In a process that requires
fairly constant heat output, the probe should be placed closed to the
heater. In a process where the heat demand is variable, the probe should
be closed to the work area. Some experiments with probe location are
often required to find this optimum position.
2-5 Sensor Installation Guidelines
2-5 Sensor Installation Guidelines
25
UM L91-Rev 8