Page
3
of
5 // email [email protected] US tel +1(603) 742 9181 Europe tel +44 (0) 1438 833577
c.
Press [STORE] [STOP] [OUT] if you need to clear maximum extension.
IMPORTANT -
The telescope shall revert to a maximum extension
located at the physical OUT switch.
d.
The MAXIMUM HEIGHT can be verified in programming mode at any time
by pressing [OUT]
6. Program any required intermediate telescope extensions
a.
There are 3 intermediate positions available, accessed by the [A], [B] and
[C] commands
b.
Position the telescope at the required intermediate position.
c.
Press [STORE] [A] to set the current position as position A.
d.
Press [STORE] [B] to set the current position as position B.
e.
Press [STORE] [C] to set the current position as position C.
f.
The programmed position can be verified in programming mode at any
time by pressing [A], [B] or [C] respectively
7. IMPORTANT:
To exit programming mode, press [STORE] [STOP] [PRESET].
The telescope and lift shall now return to running together when commanded.