AL965 Actuator Lift
Contact Closure
- Use an RJ45 connector in the
appropriate socket on the control
box to operate via contact closure
568A
568B
1
12V SUPPLY
PIN 1 NOT USED
W/G
W/O
2
12V LATCH
PIN 2 NOT USED
G
O
3
GROUND
GROUND
W/O
W/G
4
DEVICE LATCH
Short to GROUND (pin 3), device will go OUT,
remove short device will go IN.
BL
BL
5
PIN 5 NOT USED
W/BL
W/BL
N / A
6
DEVICE STOP
Momentary short to GROUND (pin 3), stops
device in current position.
O
G
N / A
7
DEVICE OUT
Momentary short to GROUND (pin 3), makes
device go OUT.
W/BR
W/BR
N / A
8
DEVICE IN
Momentary short to GROUND (pin 3), makes
device go IN.
BR
BR
N / A
PIN
DESCRIPTION
ACTION
WIRE / CABLE
CONTACT CLOSURE
LED INDICATOR