background image

Press the [Enter] and [Esc/Page] keys next 

turn ON

Press the [ /+] and [ /-] keys next turn ON

When using the CIU-3

When using the CIU-2

CIU-3

CIU-2

Double-

click

PC

6WDUWDQH[HFXWDEOH¿OHE\D

PC.

GPB-1

5.  When using the CIU-3, hold 

down the [Enter] and [Esc/

Page] keys of the GPB-1 and 

turn on the power. Release the 

[Enter] and the [Esc / Page] 

keys when the backlight of the 

screen lights up.

When using the CIU-2, hold down 
the [ /+] and [ /-] keys of the GPB-

1 and turn on the power. Release 

the [ /+] and [ /-] keys when the 

backlight of the screen lights up.

Click [OK]

Wait for about 50 seconds - 5 minutes.

Click [WRITE]

OK

WRITE

When using the CIU-2

When using the CIU-3

Don't turn off the power !

CAUTION

D o   n o t   t u r n   o f f   t h e   p o w e r  

o r   r e m o v e   t h e   b a t t e r y   w h i l e  
u p d a t i n g .  G P B - 1   m a y   b e   d a m -
a g e d .

Updater(Highspeed).exe

Updater(Lowspeed).exe

PC side

GPB-1 side

Click [OK]

If and error message appears, 
try redoing the update form the 
beginning. 

Wait for about 50 seconds - 5 minutes.

Error

6.  Turn off the power after 

t h e  c o m p l e t e d  m e s s a g e 

"

SUCCESS

"

 appears.

7.  Check the GPB-1 program 

version on the Information 

screen. 

8. Be sure to check each setting 

and check the operation 
before using.

If the cable disconnects or a contact 
failure occurs during the update, the 
update stops halfway. In that case, 
please try updating again from the be-
ginning.

If the GPB-1 fails to update or does not 
start, please have it serviced.

PC side

GPB-1 side

Summary of Contents for GYA553

Page 1: ...GYA553 Setting manual GPB 1 Ver 4 1 1M23Z07902 ...

Page 2: ... OH IURP RXU ZHEVLWH RU RXU ORFDO distribtor s website WUDFW WKH LS OH RQ RXU FRPSXWHU RQQHFW DV VKRZQ LQ WKH JXUH A PC that can connect to the Internet and has CIU 2 or CIU 3 driver software installed Double extension cable Switch Battery CIU 2 or CIU 3 To PC USB port CGY connection cable Updater Highspeed exe main bin Updater Lowspeed exe By installing the latest software Ver4 1 on the gyro prog...

Page 3: ... using the CIU 2 When using the CIU 3 Don t turn off the power CAUTION Do not turn off the power or remove the battery while updating GPB 1 may be dam aged Updater Highspeed exe Updater Lowspeed exe PC side GPB 1 side Click OK If and error message appears try redoing the update form the beginning Wait for about 50 seconds 5 minutes Error 6 Turn off the power after the completed message SUCCESS app...

Page 4: ...ter key to confirm the value Follow the instructions for the above display CAUTION Be sure to connect and disconnect the GYA553 and GPB 1 connection cable with the power off How to operate each menu screen How to operate each menu screen Use the or key to move the cursor to the setting item on the screen and press the Enter key to enter the setting mode or key to change the setting contents When yo...

Page 5: ... Using it for the first time or if the heli Gyro CGY data is loaded in GPB 1 change to GYA553 with this procedure This step is skipped when using with GYA553 from the second time onward Opening Screen Opening Screen If Gyro is not connected to GPB 1 press and hold the Enter key from the opening screen to move to this screen Press the Enter key the GYA533 setting data saved in GPB 1 is displayed WR...

Page 6: ...u Basic menu Config S BUS basic Press and hold Move the cursor Press the Enter key Battery voltage Displays the voltage of the receiver battery connected to GYA Gyro operation mode Gyro gain Displays AVCS or Normal opera tion mode and gyro gain of aileron roll elevator pitch and rudder yaw axis Esc Page Press and hold Esc Page Press and hold Esc Page Press and hold ...

Page 7: ...Set the mounting direction of GYA Set mounting GLUHFWLRQ ZLWK UHIHUHQFH WR JXUH EHORZ Move the cursor Change with these keys Confirm with Enter key Enter key to enter setting mode Config 1 7 Gyro set mounting direction ...

Page 8: ...nter key Set with the wing type tail type of GYA553 The wing type tail type of the transmitter is not used and is normal Ɣ7XUQ R WKH HOHYRQ 9 WDLO PL LQJ RQ WKH WUDQVPLWWHU VLGH Ɣ R QRW XVH WUDQVPLWWHU VXE WULP GMXVW XVLQJ WKH J UR QHXWUDO R VHW Ɣ KHQ XVLQJ WKH 6 86 VHUYR RX FDQ DOVR XVH WKH QHXWUDO R VHW IXQF tion of the S BUS servo setting parameters ...

Page 9: ...nter key to enter setting mode Change with these keys Confirm with Enter key Select the servo type according to the servo to be used Digital servo DG 285 Hz Analog servo AN 70 Hz 7KH VWDELOLW RI GLJLWDO VHUYR PRGH RI D ÀLJKW LQFUHDVHV in order to perform a high speed control action ...

Page 10: ... be connected to this port Use this port for throttle Head direction mark MODE SW DATA SW MODE LED Aileron 1 Program box S BUS 2 Aileron 2 Elevator Elevator 2 Rudder S BUS Rudder 2 DATA LED S BUS Rudder 2 Move the cursor Enter key to enter setting mode Change with these keys Confirm with Enter key CH3 THR ...

Page 11: ... aileron elevator rudder Turn the airplane to the right on the ground and check that the rudder operates to the left Tilt the airplane to the left on the ground and check that the ailerons operate to the right Raise the airplane with its nose upward and check that the elevator operates downward Key operation How to operate each menu screen How to operate each menu screen Key operation How to opera...

Page 12: ...LQ WKH UVW VHWWLQJ Config 4 7 5 7 Servo limit Adjust the value to reach the maximum operating position Adjust the value to reach the maximum operating position Maximum angle Maximum angle Stick to full right Stick to full left Aileron example Key operation How to operate each menu screen How to operate each menu screen ...

Page 13: ...transmitter LNH WKH ÀLJKW FRQGLWLRQ IXQFWLRQ RI WKH WUDQVPLWWHU RX FDQ VHW XS WR GL HUHQW GDWD IRU WKH DWWLWXGH KROGLQJ IRUFH UDWH RI WKH DLUFUDIW LQ 9 6 PRGH E RSHUDWLQJ WKH VZLWFK IURP WKH WUDQVPLWWHU DQG VZLWFK between them You can set the holding power rate selector switch to the channel with the AFR function of the transmitter and set the point for each rate on the AFR point curve to switch I...

Page 14: ...E SET on the screen and press the Enter key to enter the setting mode 2 As shown on the left screen EXECUTE Enter 1sec is displayed 3 Press and hold the Enter key to reset Set the CH for each function according to the transmitter to be used Any unused functions should be set to INH Inhibited WARNING Always verify that the S BUS function assignments match your transmitter s function in the FUNCTION...

Page 15: ......

Reviews: