38
<Model Basic Setting Procedure>
1. Model addition and call
Default setting assigns 1 model to the T12FG. To
add new models or to call a model already set, use the
Model Select function of the Linkage Menu.
This is convenient when calling a model after
registering the model names in advance. (The data of
up to 30 models can be saved at the transmitter. Data
can also be saved to the optional SD card.)
The currently called model is displayed at the top
RIWKHVFUHHQ%HIRUHÀ\LQJDQGEHIRUHFKDQJLQJDQ\
VHWWLQJVDOZD\VFRQ¿UPWKHPRGHOQDPH
When a new model is added, the Model Type Select
screen and Frequency/Modulation mode/Receiver ID
setup screen automatically appear. Change, or check
that they match the type, frequency, and receiver type
of the model used.
2. Model type and swash type selection
If a different model type is already selected, select
helicopter with the Model Type function of the
Linkage Menu, and then select the swash type matched
to the helicopter.
*The Model Type function automatically selects the
appropriate output channels, control functions, and mixing
Helicopter basic setting procedure
This section outlines examples of use of the helicopter functions of the T12FG. Adjust the actual values,
etc. to match the fuselage used.
functions for the chosen model type. Eight swash types are
available for helicopters.
*For a description of the swash type selection, refer to the
MODEL TYPE function, p.51.
3. Flight condition addition
The transmitter can install up to eight flight
conditions per model.
The Condition Select function automatically
DOORFDWHV¿YHFRQGLWLRQVIRUKHOLFRSWHU
,QLWLDOVHWWLQJ
ŏ1250$/
ŏ,'/(836:(
ŏ,'/(836:(
ŏ,'/(836:)
ŏ+2/'6:*
Note: Since you may accidentally activate
the conditions that has not been setup during
flight and this could cause a crash, delete
the conditions not used.
*For a description of the condition deletion, refer to the
&21'6(/(&7IXQFWLRQS
7KH1250$/FRQGLWLRQLVDOZD\VRQDQGUHPDLQV
on until other conditions are activated by switches.
The priority is throttle hold/idle up 2/idle up 1/
normal. Throttle hold has the highest priority.
Add other conditions, as required.
The Condition Delay can be programmed for each
channel. The Condition Delay is used to change the
servo throw smoothly when switching conditions.
*HQHUDOÀLJKWFRQGLWLRQVHWWLQJH[DPSOH
ŏ1RUPDO8VHLQLWLDOVHWWLQJFRQGLWLRQVRSHUDWH
ZKHQVZLWFK2))
8VHIURPHQJLQHVWDUWLQJWRKRYHULQJ
ŏ,GOHXS2SHUDWHDW6:(FHQWHU
8VHLQVWDOOWXUQORRSUROOLQJVWDOOWXUQDQGRWKHU
PDQHXYHUV
ŏ,GOHXS2SHUDWHDW6:(IRUZDUGVLGH
8VHLQUROOV
ŏ7KURWWOHKROG2SHUDWHDW6:*IRUZDUGVLGH