Introduction 

This instruction manual explains how to configure a Nox T3 sleep apnea testing device in KOEO 
for Sleep SMART. 

KOEO Support Phone Number 

888-505-0280 extension 4006 

KOEO Support E-mail 

[email protected]

  

KOEO Login 

app.koeo.com

 

(Please Use Google Chrome) 

Connecting the T3 Device to a Computer 

To connect a T3 device to a computer you will need to access the USB connector on the device. 
The USB connector is located under the battery lid making it inaccessible and tamper proof for 
children. 
To open the battery lid, press on the battery lid pin with the device provided in the kit, a pen, or 
a similar tool. Then slide the battery lid down and towards the bottom of the device. The T3 
device connects to the computer with a mini USB cable. The battery does not need to be 
inserted while the device is connected to the computer. 
 

 

Summary of Contents for Sleep SMART Nox T3

Page 1: ...T3 device to a computer you will need to access the USB connector on the device The USB connector is located under the battery lid making it inaccessible and tamper proof for children To open the batt...

Page 2: ...rting a Battery into the T3 Device Before you start a recording you should make sure that the device has a new fully charged AA battery To insert a new battery do the following 1 Open the battery comp...

Page 3: ...w Subject Do not enter the subject s name or Date of Birth Instead enter the following fields First Sleep SMART Box 1 Last Subject ID Number Box 2 Date of Birth 1 1 1900 Box 3 Identification Subject I...

Page 4: ...ading testing data and must be already installed on the computer you use for the set up The two main functions of KIT are as follows Set up a T3 device Upload test data from a T3 device KIT operations...

Page 5: ...e must be connected via a mini USB cable to the computer at this point The next step configures the T3 Device Step 5 T3 Setup Task in KIT Select the appropriate Time Zone from the drop down menu for t...

Page 6: ...l now proceed to Upload T3 Data Step 6 This task is to be completed only after the T3 test is complete Upon completion of the T3 test in Sleep SMART the data must be uploaded to the scoring teams for...

Page 7: ...xt Tasks in KOEO The Sleep SMART Protocol has provisions for repeated attempts under appropriate circumstances to collect data from the subject using the Nox T3 device A number of different task optio...

Page 8: ...re are extenuating circumstances that by protocol allow you to repeat the study you may do so by starting from page 1 instructions Connecting the T3 device to the computer If the Repeat T3 Setup task...

Page 9: ...con in the upper right hand corner to print out a physical copy of the Sleep SMART Sleep Apnea Test Report When printing is complete or if printing is not necessary e g subject is deceased click the c...

Reviews: