X6000 V6 Server Quick Start Guide 

Document Issue: 02 (2022-04-29)        BOM:    3150Y001 (2/3)                 

 

xFusion Digital Technologies Co., Ltd.

                                                             

                                                 

 

  

 

Copyright © xFusion Digital Technologies Co., Ltd. 2022. All Rights Reserved. 
No part of this document may be reproduced or transferred in any form or by any means without prior written consent of xFusion Digital 
Technologies Co., Ltd. 

  and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd. 

All other trademarks or trade names mentioned in this document are the property of their respective holders. 
In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which 
does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any 
meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd. shall not bear any liability resulting 
from the use of "xFusion". 
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to 
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any 
kind, either express or implied. 

1  

Introduction

 

The FusionServer X6000 V6 server (X6000 V6) is a next-generation 2U high-density server 
designed for ISPs, Internet, high-performance computing (HPC), cloud computing, and data center 
applications. Built on an architecture optimized for software-defined storage (SDS), big data, and 
software-defined infrastructure (SDI), it is ideal for large-scale server deployment. 
X6000 V6 servers feature flexible expansion, high density, reliability, energy efficiency, and easy 
O&M. 
The following table lists the X6000 V6 technical specifications. For details, see the 

FusionServer 

X6000 V6 Server User Guide

Item 

Specification 

Dimensions (H x W 
x D) 

86.1 mm (3.38 in.) x 447 mm (17.59 in.) x 900 mm (35.39 in.)   

Temperature 

 

Operating temperature: 5°C to 35°C (41°F to 95°F) (ASHRAE 

Class A2/A1 compliant) 

 

Storage temperature (within three months): 

–30°C to +60°C (–

22°F to +140°F) 

 

Storage temperature (within six months): 

–15°C to +45°C (5°F to 

113°F) 

 

Storage temperature (within one year): 

–10°C to +35°C (14°F to 

95°F) 

 

Maximum rate of temperature change: 20°C (36°F) per hour, 5°C 

(9°F) per 15 minutes

 

Relative humidity 
(RH, non-
condensing) 

 

Operating humidity: 8% to 90% 

 

Storage humidity (within three months): 8% to 85% 

 

Storage humidity (within six months): 8% to 80% 

 

Storage humidity (within one year): 20% to 75% 

 

Maximum humidity change rate: 20%/h

 

Altitude 

 

≤ 3050 m (10006.44 ft) 

 

If the server complies with ASHRAE Classes A1 and A2, the 

maximum operating temperature decreases by 1°C (1.8°F) for 

every increase of 300 m (984.25 ft) in altitude above 900 m 

(2952.76 ft). 

 

HDDs cannot be used at an altitude of over 3,050 m (10,006.44 

ft). 

 

2  

Front and Rear Panels

 

Indicators and buttons on the front panel 

 

 

Indicators of server node 1 

Indicators of server node 2 

Indicators of server node 3 

Power button/indicators 

Indicators of server node 4 

Unit Identification Light (UID) button 

Server node switchover button 

Server node health indicator 

Server node UID indicators 

10 

Server node indicators 

11 

USB 2.0 port 

12 

VGA ports 

13 

Drive 

14 

Slide-out label plate (with an SN label) 

 

Rear panel

 

Rear panel of a server with four XH321 V6 server nodes 

 

Air-cooled server node 1 

Air-cooled server node 2 

Air-cooled server node 3 

Air-cooled server node 4 

 
Rear panel of a server with four XH321C V6 server nodes 

 

Liquid-cooled server node 1 

Liquid-cooled server node 2 

Liquid-cooled server node 3   

Liquid-cooled server node 4 

 

3  

Indicators and Buttons

 

No. 

Indicator/B

utton 

Description 

Power 
button/Indi
cator 

Indicates the power status of the selected server node. For details, 
see the server node indicator descriptions. 

 

Off: The device is not powered on. 

 

Steady green: The device is powered on. 

 

Blinking yellow: The iBMC is starting. The power button is locked 

and cannot be pressed. The iBMC is started in about 1 minute, and 

then the power indicator is steady green. 

 

Steady yellow: The device is standby. 

 

Power button description: 

 

When the device is powered on, you can press this button to 

gracefully shut down the OS. 

Power button description: 

 

When the device is powered on, you can press this button to 

No. 

Indicator/B

utton 

Description 

gracefully shut down the OS. 

NOTE 
For different OSs, you may need to shut down the OS as prompted. 

 

When the device is powered on, you can hold down this button for 6 

seconds to forcibly power off the device. 

 

When the power indicator is steady yellow, you can press this button 

to power on the device. 

UID button 

The UID button is used to locate the server node to be operated. 
UID button: 

 

You can press the UID button or use the iBMC remote control to turn 

on or off the UID indicator of a server node. 

 

You can press the UID button to turn on or off the UID indicator of a 

server node. 

 

You can press and hold down the UID button for 4 to 6 seconds to 

reset the iBMC of the server node. 

Server 
node 
switchover 
button 

Press the server node switchover button to switch to the selected 
server node. When a server node is selected, its indicator is steady 
white. 
NOTE 
If the server is not fully configured with server nodes, the system 
automatically skips vacant server node positions after you press the 
node switchover button, and switches among detected server 
nodes. If there are only three server nodes (server node 1, server 
node 2, and server node 4), server node 3 is skipped automatically 
when a switchover is initiated. 

Server 
node 
health 
indicator 

Indicates the health status of each server node. 

 

Off: There is no power supply, or the server node is faulty. 

 

Blinking red at 1 Hz: A major alarm has been generated on the 

system. 

 

Blinking red at 5 Hz: A critical alarm has been generated on the 

system. 

 

Steady green: The device is operating properly. 

Server 
node UID 
indicator 

The UID indicator is used to locate the server node to be operated. 

 

Off: The device is not being located. 

 

Blinking or steady blue: The device is being located.

 

10 

Server 
node 
indicator 

Indicates whether a server node is selected. 

 

Off: The server node is not selected. 

 

Steady white: The server node is selected. 

NOTE 

 

Press the server node switchover button to switch to the selected 

server node. 

 

When a server node is selected, connection to the server node is 

switched to the power button/indicator and UID button on the left 

mounting ear as well as the VGA and USB ports on the right 

mounting ear. 

 

4  

Installation

 

 

At least three people are required to move the device. Otherwise, personal injury or device 
damage may occur. 

1. 

Install the server. 

(1) 

Lift the server vertically from both sides, place it on the guide rails, and push it into the 
cabinet. At least three people are required to do the work. See (1) in the following 
figure. 

(2) 

Align both sides of the server with the mounting bars and tighten the captive screws 
on the panel. See (2) in the following figure. 