![Fusion Sport SMARTSHOXX User Manual Download Page 2](http://html1.mh-extra.com/html/fusion-sport/smartshoxx/smartshoxx_user-manual_2351204002.webp)
Elite Performance at the Speed of Light – Limited Only by Your Imagination
SMARTSHOXX User Manual
www.fusionsport.com
Intensity:
(Dip switch one)
Easy (default)
Medium
Hard
Very hard
2.
Special Functions
(Dip Switch Two) – on the second dip switch module, you can configure two
additional things:
a.
G-select
(left switch) – this switch is a multiplier of the Intensity dip switch. There are
therefore 8 sensitivity settings – Easy/g-Low, Medium/g-Low, Hard/g-Low, Very Hard/g-Low,
Easy/g-High, Medium/g-High, Hard/g-High, Very Hard/g-High.
b.
Re-arm time
– after the initial impact, SMARTSHOXX will ignore further signals until the unit
is “rearmed”. This is used to ignore continuing vibrations in an object after the initial impact. If
your target is prone to a lot of shaking after the impact (such as a thin plastic board), selecting
a longer re-arm time will ignore any false signals. NOTE – if you need any additional fine
tuning of the rearm time, this can be set in the OPTIONS tab of the SMARTSPEED software
in many protocols.
For sensitive applications such as fencing, athletics starts and other slight movements or vibrations, select the
LOW g-Select
position for switch 1. For all other applications, such as ball targets, impact shields or tackle
bags use the
HIGH g-select
setting.
If you have any questions please do not hesitate to contact
Special-
Functions:
(Dip switch two)
g-Select
(Switch 1)
low high low
High
(default)
Retriggering time (ms)
(Switch 2)
50ms 50ms 300ms 300ms