![Furuno TZTL12F Installation Manual Download Page 13](http://html1.mh-extra.com/html/furuno/tztl12f/tztl12f_installation-manual_2349657013.webp)
1. MOUNTING
1-7
Installation procedure
1. With the boat hauled out of the water, mark the location chosen for mounting the
transducer on the bottom of the hull.
2. If the hull is not level within 15° in any direction, fairing blocks made out of teak
should be used between the transducer and hull, both inside and outside, to keep
the transducer face parallel with the water line. Fabricate the fairing block as
shown below and make the entire surface as smooth as possible to provide an
undisturbed flow of water around the transducer. The fairing block should be
smaller than the transducer itself to provide a channel to divert turbulent water
around the sides of the transducer rather than over its face.
3. Drill a hole just large enough to pass the threaded stuffing tube of the transducer
through the hull, making sure it is drilled vertically.
4. Apply a sufficient amount of high quality caulking compound to the top surface of
the transducer, around the threads of the stuffing tube and inside the mounting
hole (and fairing blocks if used) to ensure watertight mounting.
5. Mount the transducer and fairing blocks and tighten the locknut. Be sure that the
transducer is properly oriented and its working face is parallel to the waterline.
Note:
Do not over-stress the stuffing tube and locknut through excessive tightening,
since the wood block will swell when the boat is placed in the water. It is suggested
that the nut be tightened lightly at installation and re-tightened several days after the
boat has been launched.
Hole for
stuffing tube
Saw along
slope of hull.
Upper Half
Lower Half
BOW
Flat Hull
Deep-V Hull
Flat Washer
Rubber Washer
Fairing
Block
Hull
Hull
Flat Washer
Rubber
Washer
Cork
Washer
Summary of Contents for TZTL12F
Page 34: ...2 WIRING 2 12 This page is intentionally left blank ...
Page 52: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 2 ...
Page 53: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 3 ...
Page 54: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 4 ...
Page 55: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 5 ...
Page 59: ...D 1 ...
Page 60: ...D 2 ...
Page 61: ...27 Aug 2014 H MAKI D 3 ...
Page 62: ...27 Aug 2014 H MAKI D 4 ...
Page 63: ...27 Aug 2014 H MAKI D 5 ...
Page 64: ...27 Aug 2014 H MAKI D 6 ...
Page 65: ...D 7 ...
Page 66: ...1 Sep 2014 H MAKI D 8 ...