7
3. Press the [+] or [-] key to change interval.
4. Press the [AUTO] and [TRUE] keys to-
gether more than two seconds to return to
the normal mode. The STATUS LED blinks
while the equipment is being calibrated and
lights when the calibration is completed (re-
turn to normal mode). Do not operate the
equipment while the LED is blinking; cali-
bration will be incomplete.
Setting the output sentence(s)
Select which type(s) of heading data to
output. The default setting is HDG.
1. Disconnect the power connector from the
sensor.
2. Reattach the connector to the sensor while
pressing the [-] key. The PG-1000 is pow-
ered on, and LED(s) light to show which
output sentence(s) is being output.
AUTO
TRUE
CALIB
STATUS
:On (current selection)
:Off
HDG
HDT
HDM
HCC
sentence
HDG
HDT
HDM
HCC
: Magnetic heading,
Magnetic variation value
: True heading
: Magnetic heading
: Compass heading
Figure 17 LED and output sentence
3. Press key(s) corresponding to sentence(s)
to output. For example, press the [TRUE]
key to output HDT.
Note 1: Several sentences may be output
simultaneously. However, delay may
result when the output interval is 100 ms
or 200 ms.
Note 2: "HDT" outputs true heading data.
However, if variation data is not input
from the GPS navigator, magnetic bearing
will be output.
4. Press the [AUTO] and [TRUE] keys to-
gether more than two seconds to return to
the normal mode. The STATUS LED blinks
while the equipment is being calibrated and
lights when the calibration is completed (re-
turn to normal mode). Do not operate the
equipment while the LED is blinking; cali-
bration will be incomplete.
Summary of Contents for PG-1000
Page 1: ...INTEGRATED HEADING SENSOR MODEL PG 1000...
Page 21: ......
Page 22: ......
Page 23: ......