Maintenance 

Self test 1 

The unit performs an internal self-check in 
the following sequence each time power is 
turned on. 
1.  LEDs CR7 to CR10 blink twice every 2 

seconds. 

2.  ROM and RAM are tested. 
3.  LED CR6 blinks every second for normal 

operation. If an error is detected during 
the test, the corresponding LED is turned 
on. 

  When CR7 is on, ROM is defective. 

  When CR8 is on, RAM is defective. 

 

Self test 2 

The test requires an external loop to check 
I/O. Follow the steps below to carry out the 
test. 
1.  Set the DIP switch #4 of S1 to the ON 

position. 

2.  Temporarily disconnect input and output 

connectors J2 and J4. 

3.  Construct a pair of short connector 

assemblies as below. 

1
2
3
4

1
2
3
4
5
6

RS422_OUT_A
RS422_OUT_B

For J4, J5, J6 ,J7 and J8

For J9

J2

J2

XH4P

XH6P

NC

NC

NC

NC

GND

GND

RD_H

RD_C

1
2
3
4
5

1
2
3
4
5
6

RS422_OUT_A
RS422_OUT_B

XH5P

XH6P

NC
NC

NC

NC

NC

GND

GND

RD_H

RD_C

 

Short connector assy 

 
4.  Connect the XH6P-XH4P short connector 

assy. between J2 and J4. 

5.  Confirm that each LED lights according 

to equipment status as follows: 

 

CR2 

Lights when receiving NMEA data 
from J2. 

CR4 

Lights when sending NMEA data 
to J4 thru J9. 

CR6 

Blinks every second. 

CR7 

Lights when ROM error is 
detected. 

CR8 

Lights when RAM error is 
detected. 

CR9 

Lights when SIO error is detected.

CR10

Normally off. 

 
5.  Remove the connector from J4 and plug 

it into J5, J6, J7 and J8 successively, 
confirming that CR2 and CR9 light as 
below for each port. Then, remove the 
XH6P-XH4P short connector assy., plug 
in the XH6P-XH5P short connector assy. 
between J2 and J9, and confirm that CR2 
and CR9 light as below. 

CR2 

Lights when receiving NMEA data 
at J2. 

CR9 

Lights when SIO error is detected.

 
6.  Remove the XH6P-XH5P short 

connector assy. Plug in the XH6P-XH4P 
short connector assy. between J3 and J4, 
J5, J6, J7 and J8 successively. Confirm 
that LEDs light or blink as below. 
Remove the XH6P-XH4P short 
connector assy., plug in the XH6P-XH5P 
short connector assy. between J3 and J9 
and confirm that the LEDs light or blink 
as below. 

CR3 

Lights when receiving NMEA data 
at J3. 

CR4 

Lights when sending NMEA data 
to J4 thru J9. 

CR6 

Blinks every second. 

CR9 

Lights when SIO error is detected.

The relay contact signal output is turned on 
and off alternately every second during the 
test. 
 

Fuse replacement 

If the fuse blows, find the cause of the 
problem before replacing it. Do no use a fuse 
rated more than 0.5A, since it may cause 
more serious damage to the equipment. 

Summary of Contents for INTERFACE UNIT IF-2500

Page 1: ...INTERFACE UNIT IF 2500 TENI 0307 PUB No OMC 43421 A1 IF 2500...

Page 2: ...t away from air conditioner vents Keep the equipment out of direct sunlight Vibration should be minimal The location should be free of water spray CAUTION Observe the following compass safe distances...

Page 3: ...S Overview 1 Installation materials 1 Spare parts 1 Cables 2 Mounting 2 Grounding 2 Selection of output data format 2 Cable fabrication 2 Maintenance 5 SPECIFICATIONS PACKING LIST OUTLINE DRAWING INTE...

Page 4: ...nce with priority order Output data is converted to NMEA current loop IEC 61162 1 or contact signal and output Outputs data in accordance with priority order Input 1 GPS navigator Input 2 GPS navigato...

Page 5: ...utput data format The output data format is selectable by changing a jumper block A for IEC61162 1 and B for NMEA For example to select NMEA for J4 change the jumper block from A to B on JP401 and JP4...

Page 6: ...h cable Heat shrink tube Heat shrink tube Cut unused cores and solder them to shield Twist and solder Supplied 28 mm 15 mm 15 mm 30 mm 35 mm 75 mm Sheath Armor 3 mm 3 mm Fix the cable with the cable c...

Page 7: ...Input port 2 Input port 1 Jumper A IEC61162 1 B Current loop B A B A B A B A A B B A A B B A B A B A B A B A Parts location Alarm output 1 Arrival Alarm Alarm output 2 Cross Track Error Alarm Alarm ou...

Page 8: ...data to J4 thru J9 CR6 Blinks every second CR7 Lights when ROM error is detected CR8 Lights when RAM error is detected CR9 Lights when SIO error is detected CR10 Normally off 5 Remove the connector f...

Page 9: ...vailable to distribute three outputs from two independent inputs 1 Port Input 2 ports IEC61162 1 Output 6 ports IEC61162 1 or Current loop Alarm signal Output 3 ports Relay contact 2 Alarm signal Rece...

Page 10: ......

Page 11: ...ASSY MJ A6SPF0012 100 64S4071 000 133 817 1 TAPPING SCREW 4X16 SUS304 1 000 802 080 4 XH XH CONNECTOR ASSY XH6P 002 000 000 991 2 1 XH XH CONNECTOR ASSY XH5P 002 000 000 992 1 1 XH XH CONNECTOR ASSY...

Page 12: ...x2P OR P CURRENT LOOP OUTPUT IEC61162 1 J7 XH4P J8 XH4P NC 1 2 3 TD H TD B TD C TD A CO 0 2x2P OR P CURRENT LOOP OUTPUT IEC61162 1 1 2 3 CO 0 2x2P OR P GND 4 5 NC J9 XH5P J10 XH3P ALARM OUTPUT ARRIVAL...

Reviews: