Furuno INTERFACE UNIT IF-2500 Operator'S Manual Download Page 12

C

B

1

2

3

D

A

DWG.No.

SCALE

CHECKED

APPROVED

DRAWN

MASS

kg

名称

NAME

TITLE

INTERCONNECTION DIAGRAM

相互結線図

IF‑2500
インターフェイスユニット

INTERFACE UNIT

NOTE
*1. SHIPYARD SUPPLY.

注記
*1)造船所手配。
*2)内部の設定で切替え。

P

RD‑H
RD‑C

1
2
3
4
5
6

NC
NC

NC
GND

J3(XH6P)

P

RD‑H
RD‑C

1
2
3
4
5
6

NC
NC

NC
GND

J2(XH6P)

1
2

P

DC+
DC‑

NC

GND

1
2
3
4

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

J5(XH4P)

出力

CURRENT LOOP

NC

GND

1
2
3
4

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

出力

CURRENT LOOP

J4(XH4P)

OUTPUT

OUTPUT

IEC61162‑1/

IEC61162‑1/

NC

GND

1
2
3
4

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

出力

CURRENT LOOP

OUTPUT

IEC61162‑1/

J6(XH4P)

NC

GND

1
2
3
4

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

出力

CURRENT LOOP

OUTPUT

IEC61162‑1/

NC

GND

1
2
3
4

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

出力

CURRENT LOOP

OUTPUT

IEC61162‑1/

J7(XH4P)

J8(XH4P)

NC

1
2
3

TD‑H/TD‑B
TD‑C/TD‑A

CO‑0.2x2P OR

P

出力

CURRENT LOOP

OUTPUT

IEC61162‑1/

1
2
3

CO‑0.2x2P OR

P

GND

4
5

NC

J9(XH5P)

J10(XH3P)

ALARM OUTPUT (ARRIVAL)

アラーム出力(接近警報)

ALARM‑OUT1‑H
ALARM‑OUT1‑C

GND

1
2
3

CO‑0.2x2P OR

P

GND

1
2
3

CO‑0.2x2P OR

P

GND

J11(XH3P)

アラーム出力(オフトラック)
ALARM OUTPUT (OFF TRACK)

アラーム出力(受信不良)
ALARM OUTPUT (RECEIVING ERROR)

ALARM‑OUT3‑H
ALARM‑OUT3‑C

J12(XH3P)

*2

*2

*2

*2

*2

*2

CO‑0.2x2P OR

CO‑0.2x2P OR

データ入力
IEC61162‑1

DATA INPUT

航法装置
NAVIGATOR

航法装置
NAVIGATOR

*2. SELECT CURRENT LOOP OR IEC61162‑1 BY INNER SETTING.

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

TTYCS‑1 *1

C4342‑C02‑ A

31 July '03

H.MAKI

優先順位 (Priority): J2 > J3

TTYCS‑1 *1

TTYCS‑1 *1

ALARM‑OUT2‑H
ALARM‑OUT2‑C

インターフェイスユニット
INTERFACE UNIT

IF‑2500

J1(VH2P)

アース銅板 *1
COPPER STRAP

VCTF1.25x2C/VH2P,3m,φ7.4

12‑24VDC

CO‑0.2x2P: CO‑SPEVV‑SB‑C 0.2x2P,φ10.5

Takahashi T

Takahashi T

Summary of Contents for INTERFACE UNIT IF-2500

Page 1: ...INTERFACE UNIT IF 2500 TENI 0307 PUB No OMC 43421 A1 IF 2500...

Page 2: ...t away from air conditioner vents Keep the equipment out of direct sunlight Vibration should be minimal The location should be free of water spray CAUTION Observe the following compass safe distances...

Page 3: ...S Overview 1 Installation materials 1 Spare parts 1 Cables 2 Mounting 2 Grounding 2 Selection of output data format 2 Cable fabrication 2 Maintenance 5 SPECIFICATIONS PACKING LIST OUTLINE DRAWING INTE...

Page 4: ...nce with priority order Output data is converted to NMEA current loop IEC 61162 1 or contact signal and output Outputs data in accordance with priority order Input 1 GPS navigator Input 2 GPS navigato...

Page 5: ...utput data format The output data format is selectable by changing a jumper block A for IEC61162 1 and B for NMEA For example to select NMEA for J4 change the jumper block from A to B on JP401 and JP4...

Page 6: ...h cable Heat shrink tube Heat shrink tube Cut unused cores and solder them to shield Twist and solder Supplied 28 mm 15 mm 15 mm 30 mm 35 mm 75 mm Sheath Armor 3 mm 3 mm Fix the cable with the cable c...

Page 7: ...Input port 2 Input port 1 Jumper A IEC61162 1 B Current loop B A B A B A B A A B B A A B B A B A B A B A B A Parts location Alarm output 1 Arrival Alarm Alarm output 2 Cross Track Error Alarm Alarm ou...

Page 8: ...data to J4 thru J9 CR6 Blinks every second CR7 Lights when ROM error is detected CR8 Lights when RAM error is detected CR9 Lights when SIO error is detected CR10 Normally off 5 Remove the connector f...

Page 9: ...vailable to distribute three outputs from two independent inputs 1 Port Input 2 ports IEC61162 1 Output 6 ports IEC61162 1 or Current loop Alarm signal Output 3 ports Relay contact 2 Alarm signal Rece...

Page 10: ......

Page 11: ...ASSY MJ A6SPF0012 100 64S4071 000 133 817 1 TAPPING SCREW 4X16 SUS304 1 000 802 080 4 XH XH CONNECTOR ASSY XH6P 002 000 000 991 2 1 XH XH CONNECTOR ASSY XH5P 002 000 000 992 1 1 XH XH CONNECTOR ASSY...

Page 12: ...x2P OR P CURRENT LOOP OUTPUT IEC61162 1 J7 XH4P J8 XH4P NC 1 2 3 TD H TD B TD C TD A CO 0 2x2P OR P CURRENT LOOP OUTPUT IEC61162 1 1 2 3 CO 0 2x2P OR P GND 4 5 NC J9 XH5P J10 XH3P ALARM OUTPUT ARRIVAL...

Reviews: