8. MAINTENANCE, TROUBLESHOOTING
8-17
6. Push the RESET button (green) on the raise/lower control box.
7. Close the cover.
8. Turn on the breaker at the ship’s mains.
If you force quit the system at step 1, go to the step 8.
9. Turn on the system from the control unit.
10. Press the
key on the control unit to raise the transducer.
If the transducer cannot be raised, the shaft may be bent. In this case raise it manually
with the ratchet wrench, following the instructions in the next section.
RESET button
Push RESET
button.
Protection circuit
activated
Protection circuit
deactivated (normal)
Green when
protection circuit is
deactivated.
Summary of Contents for FSV-2S