41
Current Consumption, Environment & Reliability
Current Consumption
About 100 mA
(Basic Current Consumption)
About 540 mA
(Transmitting/receiving via wireless LAN)
(For details see “20. Battery Life Calculation” on later page.)
Ambient Temperature
- 5 to +45°C
(Operating)
-10 to +60°C
(Storage)
0 to +40°C
(Charging)
Humidity
20 to 85%RH
(Without condensing) (Operating)
20 to 85%RH
(Without condensing) (Storage)
Once that condensed, performance can not be assured even if the unit is dried.
Vibration
9.8 m/s
²
(10 to 55 Hz, 5.0 to 0.17 mm)
(Operating)
9.8 m/s
²
(10 to 55 Hz, 5.0 to 0.17 mm)
(Storage)
Mechanical Shock
Withstands one time of free fall from 2.0 m height. (Without package)
(Unit may be used continually for the time being.)
Static Discharge
±
20 kV (Connector pins are excluded.) (Air Discharge)
±
10 kV (Connector pins are excluded.) (Contact Discharge)
Complies with: IEC 1000-4-2
Dusts
General shops or warehouses for logistics
Corrosive Gas
General shops or warehouses for logistics
Flammability
Similar to: UL94 HB (Outer housing only)
(Flammability similar to UL94 HB is expected when considering the material or
design employed in the unit.)
Splashproof
Complies with: IEC529 IPX4
Compliance
IEC60950
MTBF
About 13000 hours (By calculation)
Substitutional modules (laser module, LCD and SS wireless LAN module) are
excluded from the calculation.
NOTE: The above-listed data are not guaranteed values but the ones obtained by factory
test.
The above-listed data may not be obtainable locally if test is performed in the
environment (test facilities etc.) different from the factory.