9
2.1
Installing the instrument
Place the adhesive drill template on the desired location for the instrument. Drill the 2
holes using a 5 mm (
1
/
4
") drill for the two pin bolts. Use a 63 mm (2½") hole saw to
machine the clearance hole for the instrument connection socket. Remove the
template.
•
Screw the two pinbolts to the instrument
•
Put the instrument in place
•
Screw the two nuts from the back
Note! The two nuts must just be tighten by hand
•
Run the Nexus Network cable from the Server to
the instrument.
•
If you want to cut the Nexus Network cable to
length, disconnect 4-pole jack plug and cut the
cable. Peel off about 35 mm (1,4") of the cable
insulation. Remove about 6 mm (1/4") from the 3
isolated wires (the 4th wire is an earth / screen).
Attach the 4 cable protectors to the wires using a
pair of flat pliers.
•
Connect the 4 cable protectors to the 4-pole jack
plug as shown. Apply silicon paste on all locations
as shown.
Note: Must be done to avoid corrosion.
Silicon paste