SP - 2
3. I/O DATA
(1) Input Data
NMEA0183(Ver.1.5/2.0), current loop
RMA: L/L, ground track speed, advance course
RMB: Waypoint bearing/distance, cross track error
RMC: L/L(GPS), ground track speed, advance course
BWC: Waypoint bearing/distance
BWR: Waypoint bearing/distance
GLL:
L/L
VTG: Ground track speed, advance course
VHW: Water track speed, advance course
MTW: Water temperature
XTE: Cross track error
(2) Output Data
NMEA0183(Ver.1.5/2.0), RS-422, output period: 2 sec.
SDDBT(Ver1.5): Depth (ft, m, fa)
SDDPT(Ver2.0): Depth (m)
YCMTW*: Water temperature
VWVHW*: Water track speed
*: Speed/temperature sensor is required.
4. POWER SUPPLY
(1) Voltage and Current
12 - 24 VDC: 1.5 - 0.5 A
5. DIMENSIONS AND MASS
See Outline Drawing
6. ENVIRONMENTAL CONDITION
(1) Temperature
-15 °C to +55 °C
(2) Relative Humidity
95% or less at 40 °C
(3) Waterproofing
IEC IPX5
(4) Category of Equipment Units
Display Unit:
To be installed in a protected area
7. COATING COLOR
(1) Display Unit
Panel: N3.0 Newtone No.5
Chassis:
2.5GY5/1.5