Furuno Ethernet Hub Hub-101 Installation Manual Download Page 5

5

Turning Power on, LED function

No operation is required for the user. Simply turn on the HUB-101’s DC power source to power it.

LED display

There are LEDs to monitor power and LAN communication on the unit. The LEDs light, blink or go 
off according to equipment status as the table shown below. The LEDs show link, mode (full-du-
plex or half-duplex) and collision statuses. When the equipment is powered, LEDs light as follow-
ing;

Power on sequence

• Power LED: ON
• LAN LEDs: Blink once, then go off.

LED

Status

Meaning

Power

On
Off

Equipment powered
Equipment off

LAN LED (yellow)

On
Off
Blinking

Full-duplex
Half-duplex
Data collision

LAN LED (green)

On
Off
Blinking

Connected to terminal
Disconnected from terminal
Data TX or RX

Power LED

LAN LED

Green

Yellow

Summary of Contents for Ethernet Hub Hub-101

Page 1: ...ash Water in the unit can result in fire electrical shock or damage the equipment Use only the specific power cable Fire or damage to the equipment can result if a different cable is used Do not disassemble or modify the equipment Fire electrical shock or sirious injury can result Observe the following compass safe distances to prevent interference to a magnetic compass CAUTION HUB 101 0 80 m 0 50...

Page 2: ...EC 60945 Ed 4 Dustproofing waterproofing IP20 IEC 60529 Power supply 12 24 VDC 0 5 0 25 A Body color N2 5 Name Type Code No Qty Remarks Ethernet HUB HUB 101 1 Installation materials MOD Z072 050 000 167 176 10 1 LAN cable for connection with NavNet 3D equipment VH2P MVVS0 75X2C 000 167 944 10 1 Power cable assy CP19 01101 001 027 250 1 set Self tapping screws Type 3x20 Code No 000 167 940 10 Spare...

Page 3: ... to the mounting location with four self tapping screws 3x20 referring to the outline drawing in this manual Wiring Connecting the cable assy power 1 Detach the body cover by hands 2 Loosen four pan head screws M3x8 and slide the shield cover upward to remove it 3 Unfasten two pan head screws M4x12 to remove the cable clamp 4 Connect the cable assy VH2P MVVS0 75X2C supplied to the power jack in th...

Page 4: ...ecting with PC s use the MOD WPAS0001 030 cable and set the applicable DIP switch es to OFF Connected unit Type Code No Cable length NavNet 3D equipment MOD Z072 020 000 167 175 10 2 m MOD Z072 050 000 167 176 10 5 m MOD Z072 100 000 167 177 10 10m PC MOD WPAS0001 030 000 164 609 10 3m P P P P 1 2 4 5 6 3 7 8 RJ45 HUB 101 1 2 4 5 6 3 7 8 NC NC E_TD P SW E_TD N E_RD P SW E_RD N 1 2 3 12 24VDC GND S...

Page 5: ...he table shown below The LEDs show link mode full du plex or half duplex and collision statuses When the equipment is powered LEDs light as follow ing Power on sequence Power LED ON LAN LEDs Blink once then go off LED Status Meaning Power On Off Equipment powered Equipment off LAN LED yellow On Off Blinking Full duplex Half duplex Data collision LAN LED green On Off Blinking Connected to terminal ...

Page 6: ...Oct 22 07 R Esumi ...

Reviews: