Furuno Ethernet Hub Hub-101 Installation Manual Download Page 2

2

System Configurations

The HUB-101 Ethernet HUB uses an Ethernet interface (100BASE-TX/10BASE-T) to provide the 
network communication among the NavNet 3D equipments, and PC. Eight ports are provided on 
this HUB. Three HUB-101 can be installed in a LAN series. 

Specifications ETHERNET HUB HUB-101

Equipment List

Transmission speed

Half-duplex/Full-duplex: 10 Mbps/100 Mbps

I/O Ports

8 ports

Environmental conditions Ambient temperature

-15 to 55 

°

C

Relative humidity

93% (at 40 

°

C)

EMC

IEC 60945 Ed.4

Dustproofing, waterproofing

IP20 (IEC 60529)

Power supply

12-24 VDC/0.5-0.25 A

Body color

N2.5

Name

Type

Code No.

Qty

Remarks

Ethernet HUB

HUB-101

-

1

Installation 
materials

MOD-Z072-050+

000-167-176-10

1

LAN cable (for connection with 
NavNet 3D equipment)

VH2P-MVVS0.75X2C

000-167--944-10

1

Power cable assy

CP19-01101

001-027-250

1 set

Self-tapping screws (Type: 3x20, 
Code No.: 000-167-940-10)

Spare parts

SP19-00901

001-027-240

1 set

1.5A Fuses (2 pcs, Type: FGMB 
125V 1.5A PBF, Code No.: 000-
157-464-10)

Ethernet HUB

HUB-101

12-24 VDC

NavNet 3D Equipment,
PC

: Standard supply
: Optional supply
: Local supply

VH2P-MVVS0.75X2C

cable

x8

MOD-Z072, 2/5/10 m (for NavNet 3D)
MOD-WPAS0001 (for PC)

Summary of Contents for Ethernet Hub Hub-101

Page 1: ...ash Water in the unit can result in fire electrical shock or damage the equipment Use only the specific power cable Fire or damage to the equipment can result if a different cable is used Do not disassemble or modify the equipment Fire electrical shock or sirious injury can result Observe the following compass safe distances to prevent interference to a magnetic compass CAUTION HUB 101 0 80 m 0 50...

Page 2: ...EC 60945 Ed 4 Dustproofing waterproofing IP20 IEC 60529 Power supply 12 24 VDC 0 5 0 25 A Body color N2 5 Name Type Code No Qty Remarks Ethernet HUB HUB 101 1 Installation materials MOD Z072 050 000 167 176 10 1 LAN cable for connection with NavNet 3D equipment VH2P MVVS0 75X2C 000 167 944 10 1 Power cable assy CP19 01101 001 027 250 1 set Self tapping screws Type 3x20 Code No 000 167 940 10 Spare...

Page 3: ... to the mounting location with four self tapping screws 3x20 referring to the outline drawing in this manual Wiring Connecting the cable assy power 1 Detach the body cover by hands 2 Loosen four pan head screws M3x8 and slide the shield cover upward to remove it 3 Unfasten two pan head screws M4x12 to remove the cable clamp 4 Connect the cable assy VH2P MVVS0 75X2C supplied to the power jack in th...

Page 4: ...ecting with PC s use the MOD WPAS0001 030 cable and set the applicable DIP switch es to OFF Connected unit Type Code No Cable length NavNet 3D equipment MOD Z072 020 000 167 175 10 2 m MOD Z072 050 000 167 176 10 5 m MOD Z072 100 000 167 177 10 10m PC MOD WPAS0001 030 000 164 609 10 3m P P P P 1 2 4 5 6 3 7 8 RJ45 HUB 101 1 2 4 5 6 3 7 8 NC NC E_TD P SW E_TD N E_RD P SW E_RD N 1 2 3 12 24VDC GND S...

Page 5: ...he table shown below The LEDs show link mode full du plex or half duplex and collision statuses When the equipment is powered LEDs light as follow ing Power on sequence Power LED ON LAN LEDs Blink once then go off LED Status Meaning Power On Off Equipment powered Equipment off LAN LED yellow On Off Blinking Full duplex Half duplex Data collision LAN LED green On Off Blinking Connected to terminal ...

Page 6: ...Oct 22 07 R Esumi ...

Reviews: