1. INSTALLATION OVERVIEW
1-5
1.3
Changing Power Supply Voltage
1
φ
, 50/60 Hz AC power is supplied to the transceiver unit. The transformer tap is set
at the factory according to customer’s order. If necessary, change jumper wires at the
terminal board of the transceiver unit according to the input voltage.
1. Remove the cover from the transceiver unit.
2. Disconnect the connectors J5 and J8 from the board at the upper of the transceiv-
er unit.
3. Unfasten four screws shown with arrows in above to remove the PTX6 Board.
Turn off the power at the power supply before
opening the cover.
Fire or electrical shock can result if the power is left
on.
WARNING
Use the correct fuse.
Use of wrong fuse can result in damage to the
equipment.
J8 J5