3. CUSTOMIZING THE SYSTEM
3-4
3.3 MENU 1 Menu
This menu mainly provides items for adjustment of tide parameters.
SHIP SPEED AVG : 15 sec
30 sec 60 sec
90 sec
TIDE AVERAGE
: 2 min
REF TIDE DIFF
: LAYER 1
LAYER 2 LAYER 3
BEARING MODE : 32 CMPS 360 TRUE
NAV MODE
: OFF
ON
BOTTOM SEARCH: NO
YES
BTM TIDE TRACK : OFF
ON
ALM/KEY BEEP
: OFF
ON
WT SPD DEPTH
: 2 m (2-400m)
RESET TRIP LOG : NO
YES
TEST
: NO GENERAL PANEL PATTERN
ECHO RANGE
: 150 m
TVG
: OFF
ON
GAIN
: 5 (1-40)
PANEL DIMMER
: 5 (0-7)
MENU ON INITIAL SETTINGS.
[
p
/
q
]:SELECT, [
t
/
u
]: CHANGE, [MENU]: EXIT
MENU 1
MENU 2
ALARM INSTALLATION
MENU 1 menu
SHIP SPEED AVG
Choose the averaging time for the ship’s speed display. The choices are 15, 30, 60 and 90
seconds.
TIDE AVERAGE
Choose the averaging time for the tide display. If tide speed appears to be too slow, choose
a higher setting. The choices are 15 s, and 1, 2, 3, 5, 10 and 20 minutes.
REF TIDE DIFF
Choose the reference layer for tide differential measurements, among layer 1, layer 2 and
layer 3.
BEARING MODE
You may show bearing in 32 compass points or 360 degrees.
NAV MODE
NAV MODE enables or disables the NAV mode. Choose ON to use NAV mode instead of
the water tracking mode. For further details, see paragraph 1.6.