Maintenance and Handling Instructions
7-5
Error Messages
Error Description
Cause of the error
Action
Defect in the
screening system.
Contact service
center.
Optics is dirty.
See Maintenance
chapter.
Inappropriate fiber
program is selected.
Check and correct the
program.
OUT OF SPEC
The fiber is out of
applicable range.
Cladding diameter is
out of applicable
range.
Can not splice with
S178.
Fiber is dirty.
Retry the splice from
preparation. Make
sure to clean the bare
portion of the fiber.
Inappropriate fiber
program is selected.
Check and correct the
program.
Incorrect parameter
setting for FOCUS
and FIELD.
Check and correct the
parameters.
FOCUSING ERROR Unable to focus on
the fiber.
Defect in the image
processing system.
Contact service
center.