Furukawa electric FITELwave AG20E (L) Instruction Manual Download Page 6

Green

Blinks 

LAN 2 sending/receiving data at 10/100 

Mbps. 

 

 

OFF 

LAN 2 is not connected or linked down. 

 

*1: Contact the dealer if this status continues for some while. 

*2: Contact the dealer. 

BEFORE USING PRODUCT 

(1) Preparation for installation 

Stick the anti-slip rubber.  

・Vertical installation: Attach the rubber in the specified positions on the bottom of the stay for vertical 

installation. 

・Horizontal installation: Attach the rubber in the specified positions on the equipment bottom. 

 

Bottom 

of 

stay 

for 

vertical 

Anti-slip 

rubber 

Bottom of equipment 

 

 

Secure the stay for vertical installation to the equipment if the equipment must be installed vertically. 

・Fit  the  arrow  mark  on  the  side  of  the  equipment  to  that  on  the  vertical  installation  stay  when 

attaching the vertical installation stay. * Insert the stay until a “click” is heard. 

・Pull  the  hook  on  the  bottom  of  the  vertical  installation  stay  outward  to  detach  the  vertical 

installation stay. 

 

 

 

 

 

 

 

 

 

 

-5- 

330-B1272-AH01 

Bottom  of  stay  for 

Pull hook outward. 


 

Side of equipment 

Fit arrow marks. 

Vertical installation stay 

Summary of Contents for FITELwave AG20E (L)

Page 1: ...INSTRUCTION MANUAL For F TELwave AG1600 Series I ONU EQUIPMENT FITELwave AG20E L FURUKAWA ELECTRIC CO LTD 330 B1272 AH01 ...

Page 2: ...n This product is information technology equipment that falls within the category of Class B optical termination equipment based on the standards of the Voluntary Control Council for Interference by Information Technology Equipment VCCI This equipment assumes the use in the home environment and may cause interference with nearby radios or TVs Use the equipment properly as described in the instruct...

Page 3: ...adapter fully to the end of the AC outlet Hold the AC adapter body when disconnecting the adapter from the AC outlet Do not damage or modify the power cable Do not place heavy objects on the power cord Do not heat pull or bend the cable Failure to heed this warning may result in damage to the cable leading to electric shock or fire Disconnect the AC adapter from the AC outlet and contact the deale...

Page 4: ...re moving the equipment Do not apply excessive force to the optical cables connected to the equipment The optical cables are easily affected by bending or twisting forces Handle with great care Excessive bending or twisting will break the cables Do not expose the power cable to heat sources Do not use benzene thinner or other organic solvents to clean the equipment Observe the regulations and disp...

Page 5: ...re complete Orange ON Authorization by center station is in process or not complete 1 Red Or ange Blinks Link with center station is being established or not established 1 Red ON OFF Equipment is standing by or erroneous 1 PON LINK Green Blinks In testing equipment Green ON LAN 1 is linked up at 1000 Mbps Green Blinks LAN 1 is sending receiving data at 1000 Mbps LAN 1 1000M OFF LAN 1 is not connec...

Page 6: ... in the specified positions on the equipment bottom Bottom of stay for vertical Anti slip rubber Bottom of equipment Secure the stay for vertical installation to the equipment if the equipment must be installed vertically Fit the arrow mark on the side of the equipment to that on the vertical installation stay when attaching the vertical installation stay Insert the stay until a click is heard Pul...

Page 7: ... is heard Connect the LAN cables to the user s terminals such as PCs Bring the user s terminals into the automatic negotiation mode Optical cable anel Rear p To center station AC outlet LAN cable User s terminal equipment LAN cable User s terminal equipment AC adapter Item Description AC adapter Commercial 100 VAC 50 60 Hz power LAN 1 port Fixed 10 100 1000 Mbps or automatic negotiation LAN 2 port...

Page 8: ... 3 Caution Do not install this equipment in a closed place Leave a space of 20 mm or more around it 7 330 B1272 AH01 ...

Page 9: ... is a possibility of equipment failure Contact the dealer if the equipment does not recover from the fault or in the event of another malfunction Status Check point POWER lamp does not go on Check that the power plug is connected properly LAN1 or LAN2 lamp does not go on Check that the LAN cable is connected properly Check that the LAN cable in use is category 5e or superior Check that the LAN cab...

Page 10: ...Use environment Temperature 0 to 40 humidity 30 to 80 No dew condensation Applicable standard Conforms to VCCI Class B 9 330 B1272 AH01 ...

Reviews: