English
CCD-0005506 Rev: 03-24-22
- 14 -
8 cu. ft. 12 Volt Built-in Refrigerator
10 cu. ft. 12 Volt Built-in Refrigerator
Capacity (cu. ft.)
8 cu. ft.
10 cu. ft.
Product Dimensions (W x H x D)
241/4 x 531/8 x 253/4” (616 x 1350 x 655mm)
241/4 x 601/8 x 253/4” (616 x 1528 x 655mm)
Recessed Dimensions (W x H x D) 231/4 x 525/8 x 233/4” (592 x 1338 x 604mm)
231/4 x 525/8 x 233/4” (592 x 1338 x 604mm)
Net Weight (lbs/kg)
FCR08DCGTA-BL
FCR08DCGTA-BR
118lbs / 53.5kg
FCR10DCGTA-BL
FCR10DCGTA-BR
130lbs / 59kg
FCR08DCGTA-NR
FCR08DCGTA-NL
FCR08DCGTA-KR
FCR08DCGTA-KL
126lbs / 57kg
FCR10DCGTA-NR
FCR10DCGTA-NL
FCR10DCGTA-KR
FCR10DCGTA-KL
139lbs / 63kg
Rated Power Supply Voltage
DC 12V (Min. 9.6V to max. 17V)
Rated Current
11A @ start-up & maximum cooling setting
Temperature Range
Refrigerator Compartment: +32°F ~ +50°F (0°C ~ 10°C)
Freezer Compartment: -4°F ~ +10.4°F (-20°C ~ -12°C)
Typical Runtime (Off Grid Usage,
powered by 100amp/hr battery)
49 hours @ 77°F (25°C)
31 hours @ 90°F (32.2°C)
Troubleshooting
A qualified professional is required for any servicing of the compressor drive board and the control board, otherwise it will void
the product warranty. If you encounter a problem similar to what is mentioned in the following table, try the suggested solution
below to see if you can solve the problem before calling service.
Problem
Solution
Refrigerator does not work
The circuit breaker tripped or fuse blown.
The unit temperature control dial is set to the “OFF” position.
Battery voltage might be out of operating range. Check battery voltage for 10.5V
under load.
Compressor turns on and off
frequently
The room temperature might be elevated.
The door is open or is frequently opened.
The temperature control dial is not set correctly.
The door gasket is torn or not sealing properly.
Battery voltage might be low, and dropping out of operating range. Check battery
voltage for 10.5V under load.
Refrigerator compartments are
too warm
Temperature control dial is not set correctly (see the "
Temperature Control
"
section for instructions on setting the temperature).
The door is open or is frequently opened.
The door gasket is torn or not sealing properly.
A large amount of warm or hot food was stored recently. Wait for the refrigerator to
reach its selected temperature.
The refrigerator has recently been disconnected for a period of time.
Vibrating or rattling (slight
vibration is normal)
The refrigerator is placed on uneven or weak surface.
Temperature setting, such as max position, may affect the vibration level. Refer to
the "
Temperature Control
" section.