Furrion F30-ATS Manual Download Page 2

.

N

OI

R

R

U

F

C

M

O

Furrion’s 30amp Automatic Transfer Switch with its Safe Switch Relay is used to automatically 
switch between two separate 120 volt AC power sources, these power sources can be from a 
generator, shore power cord or inverter.

The function of the 30amp Furrion Automatic Transfer Switch is to provide a safe and smooth 
switch over from an inverter or shore power cord automatically when a generator is started 
and brought online, using the added feature of a mechanical switch between contactors to 
ensure both power sources cannot be closed together which could otherwise create an over 
voltage situation on the output line.

The electrical contacts in the transfer switch are normally in the closed position for the 
shorepower feed.  

Once AC power from the Generator is sensed by the transfer switch, this will start a timer and 
automatically switch over to generator power supply after a 20-30 second delay, this is ensures 
the generator has sufficient time to run up to speed before electrical load is applied.
The transfer switch also has a added feature of a time delay bypass switch which will remove 
the 20 – 30second switching delay making it instantaneous.

INSTALLATION
PLEASE READ ALL SAFETY INSTRUCTIONS BEFORE INSTALLING THIS TRANSFER SWITCH!

WHEN PROTECTED BY A MOLDED CASE CIRCUIT BREAKER RATED TO 30AMPS OR LESS, 
THIS LINE/GENERATOR SWITCH IS RATED TO 5000 SYMMETRICAL AMPS.

BEFORE PREFORMING MAINTENANCE OR INSTALLATION PLEASE ENSURE TO ISOLATE ALL 
POWER SOURCES!

DO NOT USE THIS TRANFER SWITCH FOR MEDICAL PURPOSES OR LIFE SUPPORT.

Ensure generator is shut off and auto start feature (if applicable) is isolated. 
Confirm external power cord is disconnected and stored in an area where it cannot 
mistakenly be plugged in. 
Confirm the inverter (if used) has been disconnected.
Confirm with an AC/DC electrical tester that no voltage is present at any of the connections 
before beginning installation or maintenance.
Label all electrical parts with a warning tag to show work is in progress before beginning 
work.

Summary of Contents for F30-ATS

Page 1: ...30amp 125V Automatic Transfer Switch F30 ATS Furrions ATS is used to safely switch automatically between mutiple power sources N O I R R U F C M O...

Page 2: ...ond delay this is ensures the generator has sufficient time to run up to speed before electrical load is applied The transfer switch also has a added feature of a time delay bypass switch which will r...

Page 3: ...W FURRION PULL SMART PLUG FEATURED BELOW GENERATOR 30Amp 125 VAC 3 75KW Generator Input 2 Input 1 F30 ATS Transfer switch Output feed 100 100 50 50 75 75 50 50 50 50 70 70 15 20 20 15 15 20 20 50 50 2...

Page 4: ...AMPLE 3 100 100 50 50 75 75 50 50 50 50 70 70 15 20 20 15 15 20 20 50 50 20 30 20 30 75 75 20 20 60 60 20 20 20 20 20 20 20 20 20 DISTRIBUTION PANEL 2 SHORE POWER CORD 30Amp 125 VAC 3 75KW FURRION PUL...

Page 5: ...entry or generator output Typical examples of mounting locations are Inside seat or bed compartments Above or behind cabinets Under floor storage compartments etc To mount the ATS box the 4 screw lugs...

Page 6: ...re conductors Using the copper spade terminals which are supplied on the terminals of the F30 ATS relay crimp these to the ends on the incoming cables Connect the cables to the corresponding terminals...

Page 7: ...down power to the RV Keep the shore power cord connected and label the outlet that testing is in progress do not turn on 3 Start the Generator in the RV and wait for it to run up to speed as soon as...

Page 8: ...s from shore power to generator 2b Turn on the inverter you will hear a click as the unit automatically switches over power sources from shore power to inverter 3 Turn off shore power from the shore s...

Page 9: ...ECTS INSIDE ENCLOSURE Reasons Poor installation can cause wood chippings sawdust metal filings or other foreign matter to enter the case Unsuitable mounting position can cause condensation moisture or...

Page 10: ...O Mounting the Furrion F30 ATS Using the external lugs which are located on the outside of the box Mounting dimensions for the external lugs are Outer Lugs 139 x 182mm 5 x 11 11 64 15 32 187 33 34 5...

Page 11: ......

Page 12: ...t IN 46514 USA Toll free 1 888 354 5792 Email info furrion com 2007 2018 Furrion Ltd Furrion and the Furrion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other cou...

Reviews: